Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Approved
Type:
Floodplain Use
Address:
4242 E NORTH ST
Address NEW:
4242 E NORTH ST
Apply Date:
11/10/2025
Applicant:
Dane Donatelli
Description:
Existing Shed Located in the rear Lot.

Permit Reviews

Permit Number - TE-FPU-1125-00411
Permit Status: Approved
Permit Description: Existing Shed Located in the rear Lot.
Start Date Submittal Complete Date Status  
11/10/2025 FLOODPLAIN USE REVIEW v.1 11/13/2025 APPROVED Review Details

Conditions

Permit Number - TE-FPU-1125-00411
Permit Status: Approved
Permit Description: Existing Shed Located in the rear Lot.
Date Description Comments
11/12/2025 Floodplain Use Permit TE-FPU-1125-00411 November 12, 2025, Elevation Certificate Required The applicant is authorized to use a portion of the Special Flood Hazard Area (Panel 04019C2282L Zone AE FP) in the City of Tucson at 4242 E NORTH ST for Residential Accessory The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit: 1. This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the building or site improvements, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from new building and site improvements within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2. All work shall conform to the attached plans (TC-RES-0525-02728) which are made part of this permit. 3. Any utilities (HVAC, etc) shall be elevated to the regulatory flood elevation and certified by a registered land surveyor. The base flood elevation is 2457 FT NAVD 1988. The regulatory flood elevation is 2458 FT NAVD 1988. 4. Flood vent certification shall have a minimum of two (2) openings, on different sides of each enclosed area, having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one (1) foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwater. 5. The elevation certificate will be submitted to the engineering section of PDSD and approved before the pre-slab inspection is scheduled and again before the final inspection is scheduled. 6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard, or divert the existing flow of floodwaters from or to adjacent properties. 7. Any additional future disturbance of the floodplain including the construction of any fences, walls or accessory structures shall have separate floodplain use permit applications submitted to this office for review and approval. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.