Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Utilities Permit
Address NEW:
8969 E TANQUE VERDE RD
Apply Date:
12/27/2024
Applicant:
Donald Cherry
Description:
· REMOVE (3) EXISTING T-ARM SECTOR MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING EXISTING RRHS · REMOVE (3) EXISTING LGP18601 TMAS · RELOCATE (1) EXISTING SQUID TO NEW MOUNT · RETAIN (2) EXISTING DC TRUNKS · RETAIN (1) EXISTING FIBER TRUNK · RETAIN (6) EXISTING COAX CABLES · RETAIN (1) EXISTING RET CABLE · INSTALL (3) PROPOSED SECTOR FRAME ANTENNA MOUNT · INSTALL (1) PROPOSED MONOPOLE SECTOR FRAME ATTACHMENT ASSEMBLY · INSTALL (3) PROPOSED 2.5"Ø SCH 40 (2-7/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED 2.0"Ø SCH 40 (2-3/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RRUS · INSTALL (1) PROPOSED SQUID @ TOWER · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (1) PROPOSED RET CABLE

Permit Reviews

Permit Number - TC-UTL-1224-00109
Permit Status: Inspections complete
Permit Description: · REMOVE (3) EXISTING T-ARM SECTOR MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING EXISTING RRHS · REMOVE (3) EXISTING LGP18601 TMAS · RELOCATE (1) EXISTING SQUID TO NEW MOUNT · RETAIN (2) EXISTING DC TRUNKS · RETAIN (1) EXISTING FIBER TRUNK · RETAIN (6) EXISTING COAX CABLES · RETAIN (1) EXISTING RET CABLE · INSTALL (3) PROPOSED SECTOR FRAME ANTENNA MOUNT · INSTALL (1) PROPOSED MONOPOLE SECTOR FRAME ATTACHMENT ASSEMBLY · INSTALL (3) PROPOSED 2.5"Ø SCH 40 (2-7/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED 2.0"Ø SCH 40 (2-3/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RRUS · INSTALL (1) PROPOSED SQUID @ TOWER · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (1) PROPOSED RET CABLE
Start Date Submittal Complete Date Status  
12/27/2024 UTILITIES REVIEW v.1 01/29/2025 APPROVED Review Details

Conditions

Permit Number - TC-UTL-1224-00109
Permit Status: Inspections complete
Permit Description: · REMOVE (3) EXISTING T-ARM SECTOR MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING EXISTING RRHS · REMOVE (3) EXISTING LGP18601 TMAS · RELOCATE (1) EXISTING SQUID TO NEW MOUNT · RETAIN (2) EXISTING DC TRUNKS · RETAIN (1) EXISTING FIBER TRUNK · RETAIN (6) EXISTING COAX CABLES · RETAIN (1) EXISTING RET CABLE · INSTALL (3) PROPOSED SECTOR FRAME ANTENNA MOUNT · INSTALL (1) PROPOSED MONOPOLE SECTOR FRAME ATTACHMENT ASSEMBLY · INSTALL (3) PROPOSED 2.5"Ø SCH 40 (2-7/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED 2.0"Ø SCH 40 (2-3/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RRUS · INSTALL (1) PROPOSED SQUID @ TOWER · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (1) PROPOSED RET CABLE
Date Description Comments
12/27/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-UTL-1224-00109
Permit Description: · REMOVE (3) EXISTING T-ARM SECTOR MOUNTS · REMOVE (6) EXISTING ANTENNAS · REMOVE (6) EXISTING EXISTING RRHS · REMOVE (3) EXISTING LGP18601 TMAS · RELOCATE (1) EXISTING SQUID TO NEW MOUNT · RETAIN (2) EXISTING DC TRUNKS · RETAIN (1) EXISTING FIBER TRUNK · RETAIN (6) EXISTING COAX CABLES · RETAIN (1) EXISTING RET CABLE · INSTALL (3) PROPOSED SECTOR FRAME ANTENNA MOUNT · INSTALL (1) PROPOSED MONOPOLE SECTOR FRAME ATTACHMENT ASSEMBLY · INSTALL (3) PROPOSED 2.5"Ø SCH 40 (2-7/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED 2.0"Ø SCH 40 (2-3/8" O.D.) X 8' LONG MOUNT PIPES · INSTALL (12) PROPOSED ANTENNAS · INSTALL (9) PROPOSED RRUS · INSTALL (1) PROPOSED SQUID @ TOWER · INSTALL (3) PROPOSED 6AWG DC TRUNKS · INSTALL (1) PROPOSED 24PR FIBER TRUNK · INSTALL (1) PROPOSED RET CABLE
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/13/2025 COT - LCBU - Building Final Passed
08/13/2025 COT - LCEL - Electrical Final Passed
08/13/2025 COT - LCEL - Electrical Underground Passed
08/13/2025 COT - LCEL - Grounding/Bonding Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
10091128_DE125_T615_REV 4 MA_2024.12.20(1)_V1.PDF DOCUMENTS VIEW
CONS-10091128_AE202_AZL00615_ REV4 FCD PART A_12.18.24_V1.PDF DOCUMENTS VIEW
SA 10091128 AZPN000615 TANGUE VERDE_V1.PDF DOCUMENTS VIEW