Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
In Review
Type:
Utilities Permit
Address:
4240 N 1ST AV
Apply Date:
10/16/2024
Applicant:
Marck Sawyer
Description:
REMOVE ALL PANEL ANTENNAS · REMOVE ALL RRHs · REMOVE (E) ANTENNA MOUNTS · INSTALL (3) RMVD8-2120-18 MOUNTS · INSTALL (3) 840-370966K ANTENNAS FOR POS A1/B1/C1 · INSTALL (3) AIR6419 B77D+AIR6419 B77G STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNA FOR POS A3/B3/C3 · INSTALL (3) 4490 B5/B12A ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30s FOR P1 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14's FOR P3 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (1) DC9-48-60-24-8C-EV SQUID · RETAIN (2) DC6-48-60-18-8F SQUID CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) RADIO CARDS · INSTALL (1) 6601 CHASSIS, (1) XMU, (2) 6651 BBU CARDS & (1) 6610 IN EXISTING LTE · INSTALL (2) 15AMP BREAKERS FOR 6651 · INSTALL (1) 5AMP BREAKER AC/DC SCOPE: DC POWER PLAN REVIEW: · RETAIN EXISTING VERTIC STD -48VDC NETSURE 7100 PLANT 1000A WITH (8) RECTIFIERS · INSTALL (5) VERTV R48-2000E3 FOR A TOTAL OF (13) RECTIFIERS · RETAIN (5) C48/24-1500 CONVERTERS · INSTALL (2) 6AWG DC TRUNKS · INSTALL (1) 24 PAIR FIBER TRUNK · INSTALL (1) DC12-48-60-RM · INSTALL (6) SETS #6 TELCOFLEX-PP TO DC12 · INSTALL BREAKERS AS NEEDED PER ATT-CEM-18002 (3) 50AMP BREAKERS FOR AIR6419 B77D (3) 50AMP BREAKERS FOR AIR6419 B77G (3) 50AMP BREAKERS FOR 4490 B5/B12 (3) 50AMP BREAKERS FOR 4890 B26/B66 (3) 25AMP BREAKERS FOR 4478 B14 (3) 25AMP BREAKERS FOR 4415 B30 BATTERY CHECK: · RETAIN (8) EXISTING 170 BATTERIES (4) STRINGS TOTAL HVAC UNITS: · NO WORK - OUTDOOR EQUIPMENT

Permit Reviews

Permit Number - TC-UTL-1024-00094
Permit Status: In review
Permit Description: REMOVE ALL PANEL ANTENNAS · REMOVE ALL RRHs · REMOVE (E) ANTENNA MOUNTS · INSTALL (3) RMVD8-2120-18 MOUNTS · INSTALL (3) 840-370966K ANTENNAS FOR POS A1/B1/C1 · INSTALL (3) AIR6419 B77D+AIR6419 B77G STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNA FOR POS A3/B3/C3 · INSTALL (3) 4490 B5/B12A ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30s FOR P1 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14's FOR P3 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (1) DC9-48-60-24-8C-EV SQUID · RETAIN (2) DC6-48-60-18-8F SQUID CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) RADIO CARDS · INSTALL (1) 6601 CHASSIS, (1) XMU, (2) 6651 BBU CARDS & (1) 6610 IN EXISTING LTE · INSTALL (2) 15AMP BREAKERS FOR 6651 · INSTALL (1) 5AMP BREAKER AC/DC SCOPE: DC POWER PLAN REVIEW: · RETAIN EXISTING VERTIC STD -48VDC NETSURE 7100 PLANT 1000A WITH (8) RECTIFIERS · INSTALL (5) VERTV R48-2000E3 FOR A TOTAL OF (13) RECTIFIERS · RETAIN (5) C48/24-1500 CONVERTERS · INSTALL (2) 6AWG DC TRUNKS · INSTALL (1) 24 PAIR FIBER TRUNK · INSTALL (1) DC12-48-60-RM · INSTALL (6) SETS #6 TELCOFLEX-PP TO DC12 · INSTALL BREAKERS AS NEEDED PER ATT-CEM-18002 (3) 50AMP BREAKERS FOR AIR6419 B77D (3) 50AMP BREAKERS FOR AIR6419 B77G (3) 50AMP BREAKERS FOR 4490 B5/B12 (3) 50AMP BREAKERS FOR 4890 B26/B66 (3) 25AMP BREAKERS FOR 4478 B14 (3) 25AMP BREAKERS FOR 4415 B30 BATTERY CHECK: · RETAIN (8) EXISTING 170 BATTERIES (4) STRINGS TOTAL HVAC UNITS: · NO WORK - OUTDOOR EQUIPMENT
Start Date Submittal Complete Date Status  
10/18/2024 UTILITIES REVIEW v.1 N/A IN REVIEW Review Details

Outstanding Activity Conditions

Permit Number - TC-UTL-1024-00094
Permit Status: In review
Permit Description: REMOVE ALL PANEL ANTENNAS · REMOVE ALL RRHs · REMOVE (E) ANTENNA MOUNTS · INSTALL (3) RMVD8-2120-18 MOUNTS · INSTALL (3) 840-370966K ANTENNAS FOR POS A1/B1/C1 · INSTALL (3) AIR6419 B77D+AIR6419 B77G STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNA FOR POS A3/B3/C3 · INSTALL (3) 4490 B5/B12A ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30s FOR P1 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14's FOR P3 A/B/C TO BE INSTALLED ON (N) 8' PIPES · INSTALL (1) DC9-48-60-24-8C-EV SQUID · RETAIN (2) DC6-48-60-18-8F SQUID CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) RADIO CARDS · INSTALL (1) 6601 CHASSIS, (1) XMU, (2) 6651 BBU CARDS & (1) 6610 IN EXISTING LTE · INSTALL (2) 15AMP BREAKERS FOR 6651 · INSTALL (1) 5AMP BREAKER AC/DC SCOPE: DC POWER PLAN REVIEW: · RETAIN EXISTING VERTIC STD -48VDC NETSURE 7100 PLANT 1000A WITH (8) RECTIFIERS · INSTALL (5) VERTV R48-2000E3 FOR A TOTAL OF (13) RECTIFIERS · RETAIN (5) C48/24-1500 CONVERTERS · INSTALL (2) 6AWG DC TRUNKS · INSTALL (1) 24 PAIR FIBER TRUNK · INSTALL (1) DC12-48-60-RM · INSTALL (6) SETS #6 TELCOFLEX-PP TO DC12 · INSTALL BREAKERS AS NEEDED PER ATT-CEM-18002 (3) 50AMP BREAKERS FOR AIR6419 B77D (3) 50AMP BREAKERS FOR AIR6419 B77G (3) 50AMP BREAKERS FOR 4490 B5/B12 (3) 50AMP BREAKERS FOR 4890 B26/B66 (3) 25AMP BREAKERS FOR 4478 B14 (3) 25AMP BREAKERS FOR 4415 B30 BATTERY CHECK: · RETAIN (8) EXISTING 170 BATTERIES (4) STRINGS TOTAL HVAC UNITS: · NO WORK - OUTDOOR EQUIPMENT
Total Outstanding Activity Conditions - 1
Date Name
10/18/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.