Permit Details

Status:
Issued
Type:
Utilities Permit
Address NEW:
3201 E PRESIDIO RD
Apply Date:
06/21/2024
Applicant:
Andrew Agosto
Description:
· REMOVE ALL ANTENNAS · REMOVE ALL RRHS · REMOVE ALL TMAS · REMOVE ALL COAX · REMOVE ALL NOKIA EQUIPMENT · REMOVE (E) ANTENNA MOUNTS · RELOCATE (1) WCS-IMFQ-AMT FILTER FROM B3 TO B1 · INSTALL (3) RMVD-8-2120-18 T-ARM MOUNTS (CONMAT ITEM NO. ANT.54512) · INSTALL (15) SITEPRO P30120 MOUNT PIPE KITS (CONMAT ITEM NO. ANT.16008) · INSTALL (18) SITEPRO SCX23-K CROSSOVER KITS (CONMAT ITEM NO. ANT.55975) · INSTALL (6) SITEPRO BBPM-K2 CROSSOVER KITS (NON-CONMAT). · INSTALL (3) 840-370966K A1/B1/C1 · INSTALL (6) AIR6419 B77D (ABOVE)+AIR6419 B77G (BELOW) STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNAS ON A3/B3/C3 · INSTALL (3) 4490 B5/B12'S RADIOS ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30'S FOR A1/B1/C1 (N) 10' PIPES ON (N) MOUNT · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14'S FOR A3/B3/C3 (N) 10' PIPES ON (N) MOUNT · INSTALL (1) DC9-48-60-24-8C-EV SQUID · INSTALL (1) PWRT 606 DC TRUNK · CONNECT 4478 B14 WITH #6 TRUNK TO AVOID CONVERTERS

Permit Reviews

Permit Number - TC-UTL-0624-00029
Permit Status: Issued
Permit Description: · REMOVE ALL ANTENNAS · REMOVE ALL RRHS · REMOVE ALL TMAS · REMOVE ALL COAX · REMOVE ALL NOKIA EQUIPMENT · REMOVE (E) ANTENNA MOUNTS · RELOCATE (1) WCS-IMFQ-AMT FILTER FROM B3 TO B1 · INSTALL (3) RMVD-8-2120-18 T-ARM MOUNTS (CONMAT ITEM NO. ANT.54512) · INSTALL (15) SITEPRO P30120 MOUNT PIPE KITS (CONMAT ITEM NO. ANT.16008) · INSTALL (18) SITEPRO SCX23-K CROSSOVER KITS (CONMAT ITEM NO. ANT.55975) · INSTALL (6) SITEPRO BBPM-K2 CROSSOVER KITS (NON-CONMAT). · INSTALL (3) 840-370966K A1/B1/C1 · INSTALL (6) AIR6419 B77D (ABOVE)+AIR6419 B77G (BELOW) STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNAS ON A3/B3/C3 · INSTALL (3) 4490 B5/B12'S RADIOS ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30'S FOR A1/B1/C1 (N) 10' PIPES ON (N) MOUNT · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14'S FOR A3/B3/C3 (N) 10' PIPES ON (N) MOUNT · INSTALL (1) DC9-48-60-24-8C-EV SQUID · INSTALL (1) PWRT 606 DC TRUNK · CONNECT 4478 B14 WITH #6 TRUNK TO AVOID CONVERTERS
Start Date Submittal Complete Date Status  
06/21/2024 UTILITIES REVIEW v.1 07/26/2024 APPROVED Review Details

Conditions

Permit Number - TC-UTL-0624-00029
Permit Status: Issued
Permit Description: · REMOVE ALL ANTENNAS · REMOVE ALL RRHS · REMOVE ALL TMAS · REMOVE ALL COAX · REMOVE ALL NOKIA EQUIPMENT · REMOVE (E) ANTENNA MOUNTS · RELOCATE (1) WCS-IMFQ-AMT FILTER FROM B3 TO B1 · INSTALL (3) RMVD-8-2120-18 T-ARM MOUNTS (CONMAT ITEM NO. ANT.54512) · INSTALL (15) SITEPRO P30120 MOUNT PIPE KITS (CONMAT ITEM NO. ANT.16008) · INSTALL (18) SITEPRO SCX23-K CROSSOVER KITS (CONMAT ITEM NO. ANT.55975) · INSTALL (6) SITEPRO BBPM-K2 CROSSOVER KITS (NON-CONMAT). · INSTALL (3) 840-370966K A1/B1/C1 · INSTALL (6) AIR6419 B77D (ABOVE)+AIR6419 B77G (BELOW) STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNAS ON A3/B3/C3 · INSTALL (3) 4490 B5/B12'S RADIOS ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30'S FOR A1/B1/C1 (N) 10' PIPES ON (N) MOUNT · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14'S FOR A3/B3/C3 (N) 10' PIPES ON (N) MOUNT · INSTALL (1) DC9-48-60-24-8C-EV SQUID · INSTALL (1) PWRT 606 DC TRUNK · CONNECT 4478 B14 WITH #6 TRUNK TO AVOID CONVERTERS
Date Description Comments
09/05/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.