Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-UTL-0125-00002
Permit Details
Apply Date:
01/08/2025
Applicant:
Andrew Agosto
Description:
· REMOVE EXISTING T-ARM MOUNTS · REMOVE (15) RRHs · REMOVE (6) ANTENNAS · INSTALL (3) ERICSSON (KRE 101 2586/1K) ANTENNAS · INSTALL (3) ERICSSON (AIR6419 B77D+AIR6419 B77G STACKED) ANTENNAS · INSTALL (3) ERICSSON (KRE 101 2487/1K) ANTENNAS · INSTALL (3) RADIO 4490 B5/B12A RRHs · INSTALL (3) RADIO 4890 B25/B66A RRHs · INSTALL (3) RADIO 4415 B30 RRHs · INSTALL (3) RADIO 4478 B14 RRHs · INSTALL (3) SECTOR FRAME MOUNTS · INSTALL (1) HOISTING ANCHOR · INSTALL (1) HOISTING GRIP · INSTALL (6) MOUNTING PIPES · INSTALL (2) DC6-18-60-18-8F · EXISTING (6) COAX · EXISTING (6) 8AWG DC TRUNKS · EXISTING (2) 18 PAIR FIBER TRUNKS · EXISTING (1) DC6-48-60-18-08F
Permit Reviews
Permit Number - TC-UTL-0125-00002
Permit Status: Complete
Permit Description: · REMOVE EXISTING T-ARM MOUNTS
· REMOVE (15) RRHs
· REMOVE (6) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2586/1K) ANTENNAS
· INSTALL (3) ERICSSON (AIR6419 B77D+AIR6419 B77G STACKED) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2487/1K) ANTENNAS
· INSTALL (3) RADIO 4490 B5/B12A RRHs
· INSTALL (3) RADIO 4890 B25/B66A RRHs
· INSTALL (3) RADIO 4415 B30 RRHs
· INSTALL (3) RADIO 4478 B14 RRHs
· INSTALL (3) SECTOR FRAME MOUNTS
· INSTALL (1) HOISTING ANCHOR
· INSTALL (1) HOISTING GRIP
· INSTALL (6) MOUNTING PIPES
· INSTALL (2) DC6-18-60-18-8F
· EXISTING (6) COAX
· EXISTING (6) 8AWG DC TRUNKS
· EXISTING (2) 18 PAIR FIBER TRUNKS
· EXISTING (1) DC6-48-60-18-08F
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/13/2025 | UTILITIES REVIEW v.1 | 02/12/2025 | APPROVED |
Conditions
Permit Number - TC-UTL-0125-00002
Permit Status: Complete
Permit Description: · REMOVE EXISTING T-ARM MOUNTS
· REMOVE (15) RRHs
· REMOVE (6) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2586/1K) ANTENNAS
· INSTALL (3) ERICSSON (AIR6419 B77D+AIR6419 B77G STACKED) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2487/1K) ANTENNAS
· INSTALL (3) RADIO 4490 B5/B12A RRHs
· INSTALL (3) RADIO 4890 B25/B66A RRHs
· INSTALL (3) RADIO 4415 B30 RRHs
· INSTALL (3) RADIO 4478 B14 RRHs
· INSTALL (3) SECTOR FRAME MOUNTS
· INSTALL (1) HOISTING ANCHOR
· INSTALL (1) HOISTING GRIP
· INSTALL (6) MOUNTING PIPES
· INSTALL (2) DC6-18-60-18-8F
· EXISTING (6) COAX
· EXISTING (6) 8AWG DC TRUNKS
· EXISTING (2) 18 PAIR FIBER TRUNKS
· EXISTING (1) DC6-48-60-18-08F
| Date | Description | Comments |
|---|---|---|
| 01/13/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-UTL-0125-00002
Permite Description: · REMOVE EXISTING T-ARM MOUNTS
· REMOVE (15) RRHs
· REMOVE (6) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2586/1K) ANTENNAS
· INSTALL (3) ERICSSON (AIR6419 B77D+AIR6419 B77G STACKED) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2487/1K) ANTENNAS
· INSTALL (3) RADIO 4490 B5/B12A RRHs
· INSTALL (3) RADIO 4890 B25/B66A RRHs
· INSTALL (3) RADIO 4415 B30 RRHs
· INSTALL (3) RADIO 4478 B14 RRHs
· INSTALL (3) SECTOR FRAME MOUNTS
· INSTALL (1) HOISTING ANCHOR
· INSTALL (1) HOISTING GRIP
· INSTALL (6) MOUNTING PIPES
· INSTALL (2) DC6-18-60-18-8F
· EXISTING (6) COAX
· EXISTING (6) 8AWG DC TRUNKS
· EXISTING (2) 18 PAIR FIBER TRUNKS
· EXISTING (1) DC6-48-60-18-08F
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2025 | BULD - Electrical Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Complete
Permit Number: TC-UTL-0125-00002
Permit Description: · REMOVE EXISTING T-ARM MOUNTS
· REMOVE (15) RRHs
· REMOVE (6) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2586/1K) ANTENNAS
· INSTALL (3) ERICSSON (AIR6419 B77D+AIR6419 B77G STACKED) ANTENNAS
· INSTALL (3) ERICSSON (KRE 101 2487/1K) ANTENNAS
· INSTALL (3) RADIO 4490 B5/B12A RRHs
· INSTALL (3) RADIO 4890 B25/B66A RRHs
· INSTALL (3) RADIO 4415 B30 RRHs
· INSTALL (3) RADIO 4478 B14 RRHs
· INSTALL (3) SECTOR FRAME MOUNTS
· INSTALL (1) HOISTING ANCHOR
· INSTALL (1) HOISTING GRIP
· INSTALL (6) MOUNTING PIPES
· INSTALL (2) DC6-18-60-18-8F
· EXISTING (6) COAX
· EXISTING (6) 8AWG DC TRUNKS
· EXISTING (2) 18 PAIR FIBER TRUNKS
· EXISTING (1) DC6-48-60-18-08F
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2025 | COT - LCBU - Building Final | Passed | ||
| 08/14/2025 | COT - LCEL - Grounding/Bonding | Passed | ||
| 08/14/2025 | COT - LCEL - Electrical Final | Passed |