Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Inspections
Type:
Solar
Apply Date:
08/04/2026
Applicant:
TFS Solar
Description:
Roof mount 4.35 kW DC photovoltaic solar system; 10 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.

Permit Reviews

Permit Number - TC-SOL-0826-00464
Permit Status: Inspections
Permit Description: Roof mount 4.35 kW DC photovoltaic solar system; 10 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Start Date Submittal Complete Date Status  
08/04/2026 RESIDENTIAL SOLAR APP v.1 N/A APPROVED Review Details

Completed Inspections

Permit Status: Inspections
Permit Number: TC-SOL-0826-00464
Permit Description: Roof mount 4.35 kW DC photovoltaic solar system; 10 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 1 string. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/24/2026 BULD - Electrical Clearance Passed
09/24/2026 COT - RSOL - Electrical Final Solar Project Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-YODER JAMES PV STORAGE-DRAWINGS-8649-DESERT RAINBOW-DR_V1.PDF DOCUMENTS VIEW
YODER JAMES PV STORAGE-SAPP APPROVAL-DOCUMENT-SA20260804-9-448-30-A_V1.PDF DOCUMENTS VIEW
YODER JAMES PV STORAGE-SPECS APPROVAL-UPLOADS-SA20260804-9-448-30-A_V1.PDF DOCUMENTS VIEW