Start Date Submittal Complete Date Status  
01/06/2026 RESIDENTIAL ADD/ALT v.1 01/23/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1225-06158
Permit Status: Inspections
Permit Description: Sleeping Quarters
Total Outstanding Activity Conditions - 2
Date Name
01/22/2026 Prior to Inspections, please submit a Manual J Calculation Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
01/22/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-1225-06158
Permit Status: Inspections
Permit Description: Sleeping Quarters
Date Description Comments
01/06/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-1225-06158
Permite Description: Sleeping Quarters
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
03/03/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Not Ready Provide holdowns per plan. Remove all loose fill dirt from footings. Toe down footing not per proper depth. Add more adobes for rebar support throughout. Tape all vertical rebar supporting horizontal bar. 3/3/2026
04/14/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required Nailing not per plan, should be 4" OC for all edges, add anchor bolts at marked areas 32"oc
04/14/2026 COT - RSBU - Roof Nailing N/A Re-inspection required Nailing not per plan, should be 4" OC for all edges, add anchor bolts at marked areas 32"oc
04/15/2026 COT - RSPL - Yard Water Line N/A Canceled
06/09/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 6-9-26: fire foam all penetrations at top plates, fire foam exterior wall where line set penetrates wall, add blocking to registers at living room and bedroom, add straps to DWV and HVAC line set.
06/11/2026 COT - RSEL - Outdoor Lighting N/A Not Ready
06/30/2026 COT - RSPL - Plumbing Final N/A Not Ready 06/30/2026
Not ready.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-1225-06158
Permit Description: Sleeping Quarters
Total Completed Inspections - 9
Date Description Inspector Results Comments
02/25/2026 COT - RSPL - Rough Soil Passed Ok to cover progress areas.
03/04/2026 COT - RSBU - Excavation/Rebar/Zoning Passed All corrections have been made. 3/4/2026
03/04/2026 COT - RSBU - Preslab Passed
04/15/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Passed 4/15/26
04/15/2026 COT - RSBU - Roof Nailing Passed Passed 4/15/26
06/04/2026 COT - RSEL - Electrical Underground Passed Passed
06/04/2026 COT - RSPL - Yard Water Line Passed Passed
06/11/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
06/30/2026 COT - RSPL - Sewer Passed 06/30/2026
Holding under test to HCS with green tracer - okay to backfill, shading required.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-2845 E 2ND STREET DRAWINGS_V1.PDF DOCUMENTS VIEW