Permit: TC-RES-1224-07198
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2711 N AVENIDA EMPALME
Address NEW:
2711 N AVENIDA EMPALME
Apply Date:
12/11/2024
Applicant:
Fernando Dicochea
Description:
New pool heater gas line
Permit Reviews
Permit Number - TC-RES-1224-07198
Permit Status: Inspections
Permit Description: New pool heater gas line
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/11/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 12/12/2024 | REQUIRES RESUBMIT |
| 12/27/2024 | RESIDENTIAL SIMPLE REVIEW v.2 | 12/27/2024 | APPROVED |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1224-07198
Permit Description: New pool heater gas line
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2025 | COT - RSPL - Plumbing Final | Passed | 1-14-25, pressure test at 12psi-must see it at 15 psi for minimum of 10 minutes. 1-14-25, reinspected and approved. Plumbing final approved. Okay to backfill trench. |
|
| 01/14/2025 | COT - RSME - Mechanical Final | Passed | 1-14-25, pressure test at 12psi-must see it at 15 psi for minimum of 10 minutes. 1-14-25, reinspected and approved. Mechanical final approved-gas line properly secured.Okay to backfill trench. |
|
| 01/15/2025 | COT - BULD - SWG Clearance | Passed |