Permit: TC-RES-1224-07060
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3233 E BERMUDA ST
Address NEW:
3233 E BERMUDA ST
Apply Date:
12/05/2024
Applicant:
John Gruber
Description:
* Install all new black iron gas pipe to each fixture (Range, Water Heater, Furnace) from the new meter location. * All new piping shall be strapped and secured * All new piping shall be sized per code for each appliance * All new piping shall be pressure tested for leaks
Permit Reviews
Permit Number - TC-RES-1224-07060
Permit Status: Inspections
Permit Description: * Install all new black iron gas pipe to each fixture (Range, Water Heater, Furnace) from the new meter location.
* All new piping shall be strapped and secured
* All new piping shall be sized per code for each appliance
* All new piping shall be pressure tested for leaks
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/06/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 12/06/2024 | APPROVED |
Conditions
Permit Number - TC-RES-1224-07060
Permit Status: Inspections
Permit Description: * Install all new black iron gas pipe to each fixture (Range, Water Heater, Furnace) from the new meter location.
* All new piping shall be strapped and secured
* All new piping shall be sized per code for each appliance
* All new piping shall be pressure tested for leaks
| Date | Description | Comments |
|---|---|---|
| 12/06/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1224-07060
Permite Description: * Install all new black iron gas pipe to each fixture (Range, Water Heater, Furnace) from the new meter location.
* All new piping shall be strapped and secured
* All new piping shall be sized per code for each appliance
* All new piping shall be pressure tested for leaks
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2024 | COT - BULD - SWG Clearance | N/A | Partial Pass | 12/11/24 partial pass pending Piping on the roof at 't' is touching roof, needs to be elevated. secure pipe to stud inside by water heater. pending solar |
| 12/11/2024 | COT - RSPL - Plumbing Final | N/A | Partial Pass | 12/11/24 partial pass pending Piping on the roof at 't' is touching roof, needs to be elevated. secure pipe to stud inside by water heater. pending solar |