Permit: TC-RES-1223-10119
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1519 W NIAGARA ST
Address NEW:
1519 W NIAGARA ST
Apply Date:
12/15/2023
Applicant:
TFS Solar
Description:
roof mounted 4.92 kW DC photovoltaic solar system; 12 modules, 1 Tesla Powerwall+ inverter with 2 strings, 50A PV breaker, 14 kWh storage system; 225A bus with 200A MCB, interconnection via PCS
Permit Reviews
Permit Number - TC-RES-1223-10119
Permit Status: Complete
Permit Description: roof mounted 4.92 kW DC photovoltaic solar system; 12 modules, 1 Tesla Powerwall+ inverter with 2 strings, 50A PV breaker, 14 kWh storage system; 225A bus with 200A MCB, interconnection via PCS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/18/2023 | RESIDENTIAL SOLAR v.1 | 01/11/2024 | APPROVED |
| 03/05/2024 | RESIDENTIAL SOLAR v.1 | 03/19/2024 | APPROVED |
| 02/12/2024 | RESIDENTIAL SOLAR v.1 | 03/04/2024 | APPROVED |
| 04/30/2024 | RESIDENTIAL SOLAR v.1 | 05/16/2024 | APPROVED |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1223-10119
Permit Description: roof mounted 4.92 kW DC photovoltaic solar system; 12 modules, 1 Tesla Powerwall+ inverter with 2 strings, 50A PV breaker, 14 kWh storage system; 225A bus with 200A MCB, interconnection via PCS
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2024 | RSBU - Building Final | Passed | ||
| 06/24/2024 | COT - RSOL - Electrical Final Solar Project | Passed | ||
| 06/24/2024 | BULD - Electrical Clearance | Passed | Approved, DGC Clearance to TEP is required for the solar meter |