Permit: TC-RES-1222-01661
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
7902 E MABEL DR
Address NEW:
7902 E MABEL DR
Apply Date:
12/21/2022
Applicant:
Javier Martinez
Description:
Bedroom Suite Addition and Convert Bedroom into Bathroom
Permit Reviews
Permit Number - TC-RES-1222-01661
Permit Status: Inspections
Permit Description: Bedroom Suite Addition and Convert Bedroom into Bathroom
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/17/2023 | RESIDENTIAL NEW DWELLING v.2 | 02/09/2023 | REQUIRES RESUBMIT |
| 04/21/2023 | RESIDENTIAL NEW DWELLING v.3 | 04/27/2023 | REQUIRES RESUBMIT |
| 04/28/2023 | RESIDENTIAL NEW DWELLING v.4 | 05/23/2023 | APPROVED |
| 05/23/2023 | RESTAMP - RESIDENTIAL v.1 | 05/23/2023 | APPROVED |
| 12/27/2022 | RESIDENTIAL NEW DWELLING v.1 | 12/27/2022 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-1222-01661
Permit Status: Inspections
Permit Description: Bedroom Suite Addition and Convert Bedroom into Bathroom
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/23/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1222-01661
Permite Description: Bedroom Suite Addition and Convert Bedroom into Bathroom
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2024 | COT - RSPL - Sewer | N/A | Re-inspection required | 1-Install tracer wire. 2-Provide water test. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1222-01661
Permit Description: Bedroom Suite Addition and Convert Bedroom into Bathroom
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2023 | COT - RSBU - Preslab | Passed | 8/15/23 Need to wrap plumbing that will be exposed to concrete in foam wrap ok to pour when completed | |
| 08/15/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 8/15/23 rebar touching dirt need to raise off ground ok to pour when complete | |
| 08/15/2023 | COT - RSPL - Rough Soil | Passed | 8/15/23 Need to wrap plumbing that will be exposed to concrete in foam wrap ok to pour when completed | |
| 10/27/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 03/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to insulate and drywall walls and ceilings. | |
| 03/01/2024 | BULD - Electrical Clearance | Passed | Existing service panel, addition is on a 100amp sub panel. | |
| 03/01/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | H2.5 clips installed, sheathing is properly nailed, and bolts are secured in base plate. | |
| 03/01/2024 | COT - RSEL - Grounding/Bonding | Passed | 2 ground rods are installed 6 feet apart outside of electrical service closet. | |
| 03/01/2024 | COT - BULD - SWG Clearance | Passed | Gas line for insta hot water heater is holding 15 pounds of air pressure. | |
| 03/01/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line for insta hot water heater is holding 15 pounds of air pressure. | |
| 04/24/2024 | COT - RSPL - Sewer | Passed | 4/24/24: Green tracer wire is installed and sewer line is under a water test with no leaks. | |
| 08/09/2024 | COT - RSEL - Electrical Final | Passed | ||
| 08/09/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 08/09/2024 | COT - RSME - Mechanical Final | Passed | ||
| 08/09/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 08/09/2024 | RSBU - Building Final | Passed |