Permit: TC-RES-1125-05697
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
7438 S MADERA VILLAGE DR
Address NEW:
7438 S MADERA VILLAGE DR
Apply Date:
11/25/2025
Applicant:
Jai Walker
Description:
(1) 3 TON CONDENSER CHANGEOUT IN THE BACKYARD AND (1) 3.5 TON CONDENSER CHANGEOUT , INCLUDING 2 INDOOR COILS, AND (2) 80K BTUS FURNACE CHANGEOUT IN THE ATTIC.
Permit Reviews
Permit Number - TC-RES-1125-05697
Permit Status: Inspections
Permit Description: (1) 3 TON CONDENSER CHANGEOUT IN THE BACKYARD AND (1) 3.5 TON CONDENSER CHANGEOUT , INCLUDING 2 INDOOR COILS, AND (2) 80K BTUS FURNACE CHANGEOUT IN THE ATTIC.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/05/2025 | RESIDENTIAL SIMPLE REVIEW v.2 | 12/05/2025 | APPROVED |
| 11/25/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 11/26/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-1125-05697
Permit Status: Inspections
Permit Description: (1) 3 TON CONDENSER CHANGEOUT IN THE BACKYARD AND (1) 3.5 TON CONDENSER CHANGEOUT , INCLUDING 2 INDOOR COILS, AND (2) 80K BTUS FURNACE CHANGEOUT IN THE ATTIC.
| Date | Description | Comments |
|---|---|---|
| 11/25/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1125-05697
Permite Description: (1) 3 TON CONDENSER CHANGEOUT IN THE BACKYARD AND (1) 3.5 TON CONDENSER CHANGEOUT , INCLUDING 2 INDOOR COILS, AND (2) 80K BTUS FURNACE CHANGEOUT IN THE ATTIC.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 01/09/2026 Secure disconnect conduit whip to wall, add refrigerant caps to both AC condenser units outside. Both AC units are over-amped to 50A at main service panel - manufacturer label calls for 30A max fuse. |