Permit: TC-RES-1124-06526
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
6501 E CALLE CASTOR
Address NEW:
6501 E CALLE CASTOR
Apply Date:
11/08/2024
Applicant:
Description:
*** need back asap *** whole repipe
Permit Reviews
Permit Number - TC-RES-1124-06526
Permit Status: Complete
Permit Description: *** need back asap ***
whole repipe
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/14/2024 | RESIDENTIAL SIMPLE REVIEW v.2 | 11/14/2024 | APPROVED |
| 11/08/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 11/08/2024 | REQUIRES RESUBMIT |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-1124-06526
Permite Description: *** need back asap ***
whole repipe
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2024 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | insulate all water lines in ceiling and near bird boards. add backing to shower head. secure in place along with all the other water lines. cannot use nails to secure water lines. 11/21/2024 |
| 11/21/2024 | RSPL - Plumbing Progress | N/A | Re-inspection required | insulate all water lines in ceiling and near bird boards. add backing to shower head. secure in place along with all the other water lines. cannot use nails to secure water lines. 11/21/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1124-06526
Permit Description: *** need back asap ***
whole repipe
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/2024 | COT - RSPL - Plumbing Final | Passed | 11/22/24: Water lines in ceiling, next to bird blocking, and on exterior wall are properly insulated, backing added behind shower head, water lines are properly secured in place with copper clamps or plastic nail on straps. Okay to proceed with drywall replacement and repairs. | |
| 11/22/2024 | RSPL - Plumbing Progress | Passed | 11/22/24: Water lines in ceiling, next to bird blocking, and on exterior wall are properly insulated, backing added behind shower head, water lines are properly secured in place with copper clamps or plastic nail on straps. Okay to proceed with drywall replacement and repairs. |