Permit: TC-RES-1123-09761
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2045 E ADAMS ST
Address NEW:
2045 E ADAMS ST
Apply Date:
11/28/2023
Applicant:
Brandon Thorne
Description:
Replacing the Knob and Tube. -Run new home runs from the panel to refeed power to the different parts of the house. -Interior walls - Run new branch wire runs from each interior device box to the attic or crawlspace where we will junction to the new homerun's and install new devices. -Exterior walls - Chanel out the adobe walls enough to install a 1/2in conduit from the device box to the ceiling or crawl space and run new branch wire runs from each device box to the attic where we will junction to the new homerun's and install new devices.
Permit Reviews
Permit Number - TC-RES-1123-09761
Permit Status: Complete
Permit Description: Replacing the Knob and Tube.
-Run new home runs from the panel to refeed power to the different parts of the house.
-Interior walls - Run new branch wire runs from each interior device box to the attic or crawlspace where we will junction to the new homerun's and install new devices.
-Exterior walls - Chanel out the adobe walls enough to install a 1/2in conduit from the device box to the ceiling or crawl space and run new branch wire runs from each device box to the attic where we will junction to the new homerun's and install new devices.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/01/2023 | RESIDENTIAL NEW DWELLING v.1 | 12/27/2023 | REQUIRES RESUBMIT |
| 01/03/2024 | RESIDENTIAL NEW DWELLING v.2 | 01/08/2024 | REQUIRES RESUBMIT |
| 01/12/2024 | RESIDENTIAL NEW DWELLING v.3 | 01/12/2024 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-1123-09761
Permite Description: Replacing the Knob and Tube.
-Run new home runs from the panel to refeed power to the different parts of the house.
-Interior walls - Run new branch wire runs from each interior device box to the attic or crawlspace where we will junction to the new homerun's and install new devices.
-Exterior walls - Chanel out the adobe walls enough to install a 1/2in conduit from the device box to the ceiling or crawl space and run new branch wire runs from each device box to the attic where we will junction to the new homerun's and install new devices.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2024 | BULD - Electrical Clearance | N/A | Not Applicable | Not applicable, electrical meter was never disconnected during this project. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1123-09761
Permit Description: Replacing the Knob and Tube.
-Run new home runs from the panel to refeed power to the different parts of the house.
-Interior walls - Run new branch wire runs from each interior device box to the attic or crawlspace where we will junction to the new homerun's and install new devices.
-Exterior walls - Chanel out the adobe walls enough to install a 1/2in conduit from the device box to the ceiling or crawl space and run new branch wire runs from each device box to the attic where we will junction to the new homerun's and install new devices.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2024 | RSEL - Electrical Progress | Passed | Electrical re-wiring is complete throughout entire house. | |
| 01/29/2024 | COT - RSEL - Electrical Final | Passed | Electrical re-wiring is complete throughout the house. | |
| 02/22/2024 | RSBU - Building Final | Passed |