Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-1123-09535
Permit Details
Apply Date:
11/16/2023
Applicant:
Joseph Duchene
Description:
My Plumber will replace all potable water lines throughout home from service entry to all fixtures in home to include new emergency shut off valves and supply lines to fixtures as well as new laundry box and valves. My Plumber will be installing Wirsbo Aqua- Pex with copper stub-outs.
Permit Reviews
Permit Number - TC-RES-1123-09535
Permit Status: Issued
Permit Description: My Plumber will replace all potable water lines throughout home from service entry to all fixtures in home to include new emergency shut off valves and supply lines to fixtures as well as new laundry box and valves. My Plumber will be installing Wirsbo Aqua- Pex with copper stub-outs.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/21/2023 | RESIDENTIAL SIMPLE REVIEW v.2 | 11/21/2023 | APPROVED |
11/16/2023 | RESIDENTIAL SIMPLE REVIEW v.1 | 11/16/2023 | REQUIRES RESUBMIT |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-1123-09535
Permit Description: My Plumber will replace all potable water lines throughout home from service entry to all fixtures in home to include new emergency shut off valves and supply lines to fixtures as well as new laundry box and valves. My Plumber will be installing Wirsbo Aqua- Pex with copper stub-outs.
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2023 | COT - RSPL - Plumbing Final | Passed | 11/24/23: water hammer arrestor missing at (dishwasher, laundry room, refrigerator), seal all penetrations going through top plate, vacuum breaker missing at hose bibs, insulate copper line at exterior of house. lav in master bedroom needs to be installed to verify proper drainage. 11/28/23: corrections made. |