Permit: TC-RES-1123-09459
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2739 E PORTOBELLO DR
Address NEW:
2739 E PORTOBELLO DR
Apply Date:
11/12/2023
Applicant:
Filiberto Castillo jr
Description:
Bedroom Suite Addition
Permit Reviews
Permit Number - TC-RES-1123-09459
Permit Status: Complete
Permit Description: Bedroom Suite Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/27/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/27/2023 | APPROVED |
| 11/14/2023 | RESIDENTIAL NEW DWELLING v.1 | 12/07/2023 | APPROVED |
| 02/25/2024 | RESIDENTIAL NEW DWELLING v.1 | 03/25/2024 | APPROVED |
Conditions
Permit Number - TC-RES-1123-09459
Permit Status: Complete
Permit Description: Bedroom Suite Addition
| Date | Description | Comments |
|---|---|---|
| 12/07/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 11/30/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-1123-09459
Permite Description: Bedroom Suite Addition
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2024 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 2/14/24: sewer Waste line should be 4" per plan (installed is 3"), tracer wire missing, point of connection not made. |
| 02/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready | 2/12/24: not ready (will be scheduled for Wednesday) |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1123-09459
Permit Description: Bedroom Suite Addition
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 01/30/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 01/30/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 02/21/2024 | COT - RSPL - Rough Soil | Passed | ||
| 02/21/2024 | COT - RSBU - Preslab | Passed | ||
| 02/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 04/03/2024 | RSBU - Building Final | Passed | ||
| 04/03/2024 | COT - RSEL - Electrical Final | Passed | ||
| 04/03/2024 | COT - RSME - Mechanical Final | Passed | ||
| 04/03/2024 | COT - RSPL - Plumbing Final | Passed |