| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/13/2023 | RESIDENTIAL NEW DWELLING v.1 | 12/04/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-1123-09432
Permit Status: Inspections
Permit Description: Kitchen and Bedroom Addition
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/28/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-1123-09432
Permit Status: Inspections
Permit Description: Kitchen and Bedroom Addition
| Date | Description | Comments |
|---|---|---|
| 12/04/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1123-09432
Permite Description: Kitchen and Bedroom Addition
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2024 | COT - RSPL - Rough Soil | N/A | Partial Pass | 3/15/24: plumbing underground at kitchen extension was covered prior to inspection. Letter will need to be provided from licensed plumbing stating that all plumbing underground meets or exceeds requirements of the 2018 IRC. Prior to final |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1123-09432
Permit Description: Kitchen and Bedroom Addition
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 3/12/24: F2 footings at new slab at north east corner of house not per plan, plans call for compacted A.B.C not in at time of inspection. (2) F4 footings at west slab of house missing per plan. F3 at west slab calls for 1 #4 at top and bottom (missing per plan detail 4/A3), support reinforcement at south west corner of slab. 3/15/24: corrections made. |
|
| 03/15/2024 | COT - RSBU - Preslab | Passed | ||
| 06/24/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/24/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 08/13/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 09/10/2024 | COT - BULD - SWG Clearance | Passed | Please bond gas line 9/10/24: SWG clearance |
|
| 10/31/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 11/01/2024 | COT - RSME - Mechanical Final | Passed | ||
| 11/05/2024 | COT - RSEL - Electrical Final | Passed | ||
| 11/05/2024 | RSBU - Building Final | Passed |