Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
4357 S EVERGREEN AV
Apply Date:
11/06/2023
Applicant:
Anthony Hodges
Description:
Enclose Carport for Sleeping Quarters

Permit Reviews

Permit Number - TC-RES-1123-09286
Permit Status: Complete
Permit Description: Enclose Carport for Sleeping Quarters
Start Date Submittal Complete Date Status  
12/20/2023 RESIDENTIAL NEW DWELLING v.2 01/03/2024 APPROVED Review Details
11/07/2023 RESIDENTIAL NEW DWELLING v.1 11/28/2023 REQUIRES RESUBMIT Review Details

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-1123-09286
Permite Description: Enclose Carport for Sleeping Quarters
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/11/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 1-Bedroom has no smoke detector. 2-Receptacle in bedroom is behind drywall surface.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-1123-09286
Permit Description: Enclose Carport for Sleeping Quarters
Total Completed Inspections - 10
Date Description Inspector Results Comments
02/05/2024 COT - RSPL - Rough Soil Passed
02/16/2024 COT - RSBU - Preslab Passed
03/11/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
03/15/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3/15/24: Smoke detectors are interconnected, fire blocking and fire foam has been installed in holes through top plates and fire blocks.
04/26/2024 RSBU - Building Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and fully operational. AFCI breakers are installed in electrical panel for bedroom and dining area. GFCI outlets are installed in kitchen and bathroom.
04/26/2024 COT - RSEL - Electrical Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and fully operational. AFCI breakers are installed in electrical panel for bedroom and dining area. GFCI outlets are installed in kitchen and bathroom. Okay to issue Certificate of Completion for this permit.
04/26/2024 COT - RSPL - Plumbing Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and fully operational. AFCI breakers are installed in electrical panel for bedroom and dining area. GFCI outlets are installed in kitchen and bathroom. Okay to issue Certificate of Completion for this permit.
04/26/2024 COT - RSME - Mechanical Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and fully operational. AFCI breakers are installed in electrical panel for bedroom and dining area. GFCI outlets are installed in kitchen and bathroom. Okay to issue Certificate of Completion for this permit.
10/10/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Approved per Ralph Mellecker finals. 10/10/2024
10/10/2024 COT - RSPL - Yard Water Line Passed Approved per Ralph Mellecker finals. 10/10/2024

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-BIVENS PLAN - PLANSET_V1.PDF DOCUMENTS VIEW