Permit: TC-RES-1123-09230
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3312 E ARROYO CHICO
Address NEW:
3312 E ARROYO CHICO
Apply Date:
11/02/2023
Applicant:
Maria Corella
Description:
custom home
Permit Reviews
Permit Number - TC-RES-1123-09230
Permit Status: Inspections
Permit Description: custom home
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/10/2024 | RESIDENTIAL NEW DWELLING v.2 | 05/10/2024 | REQUIRES RESUBMIT |
| 05/23/2024 | RESIDENTIAL NEW DWELLING v.4 | 06/04/2024 | APPROVED |
| 11/15/2023 | RESIDENTIAL NEW DWELLING v.2 | 01/18/2024 | APPROVED |
| 01/18/2024 | RESTAMP - RESIDENTIAL v.1 | 01/22/2024 | APPROVED |
| 11/06/2023 | RESIDENTIAL NEW DWELLING v.1 | 11/13/2023 | REQUIRES RESUBMIT |
| 05/22/2024 | RESIDENTIAL NEW DWELLING v.3 | 05/22/2024 | REQUIRES RESUBMIT |
| 06/04/2024 | RESTAMP - RESIDENTIAL v.1 | 06/05/2024 | APPROVED |
| 04/09/2024 | RESIDENTIAL NEW DWELLING v.1 | 04/09/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-1123-09230
Permit Status: Inspections
Permit Description: custom home
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 01/17/2024 | AIR BALANCING/COMMISSIONING REPORT IS REQUIRED. |
| 01/17/2024 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 01/17/2024 | Post-Installed Anchor Inspection Report is required. |
| 01/17/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
| 01/17/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1123-09230
Permite Description: custom home
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2024 | COT - RSBU - Interior Shear Bracing | N/A | Not Applicable | |
| 07/29/2025 | COT - BULD - SWG Clearance | N/A | Not Ready |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1123-09230
Permit Description: custom home
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2024 | COT - RSPL - Rough Soil | Passed | under slab | |
| 04/24/2024 | COT - RSBU - Preslab | Passed | ||
| 04/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 08/20/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 08/20/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 08/20/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 08/20/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 11/13/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading required. 11/13/2024 | |
| 12/03/2024 | COT - RSPL - Yard Water Line | Passed | 12/3/24 connected properly, ok to complete backfill, tracer wire present | |
| 02/11/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 02/20/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Ok to insulate and sheet rock walls. | |
| 07/29/2025 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 7/29/2025 |