Permit: TC-RES-1122-00468
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
372 W CORONA RD
Address NEW:
372 W CORONA RD
Apply Date:
11/04/2022
Applicant:
BRANDY PALCHETTI
Description:
• SYSTEM SIZE: 7455W DC, 6000W AC • MODULES: (21) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-355M • INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO LTD: MIN 6000TL-XH-US • RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249 • MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW 200 AMP MAIN PANEL WITH 225 AMP BUSBAR RATING WITH 200 AMP MAIN BREAKER. • SIEMENS MC2442B1200EFV/SV OR EQUIVALENT • RAPID SHUTDOWN: (21) TIGO ENERGY, INC TS4-A-F ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
Permit Reviews
Permit Number - TC-RES-1122-00468
Permit Status: Expired
Permit Description: • SYSTEM SIZE: 7455W DC, 6000W AC
• MODULES: (21) LONGI GREEN ENERGY TECHNOLOGY CO
LTD: LR4-60HPB-355M
• INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO
LTD: MIN 6000TL-XH-US
• RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE
WITH STANDOFF TO RAFTER: SNR-DC-01249
• MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN
PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED
WITH NEW 200 AMP MAIN PANEL WITH 225 AMP BUSBAR
RATING WITH 200 AMP MAIN BREAKER.
• SIEMENS MC2442B1200EFV/SV OR EQUIVALENT
• RAPID SHUTDOWN: (21) TIGO ENERGY, INC TS4-A-F
ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/14/2022 | RESIDENTIAL SOLAR v.1 | 12/13/2022 | REQUIRES RESUBMIT |