Status:
Issued
Type:
Residential Building - One or Two Family
Address:
3538 E 23RD ST
Address NEW:
3538 E 23RD ST
Apply Date:
09/18/2026
Applicant:
Stephen Jobe
Description:
REV1_Additional Gas piping Installation. Abandon existing piping and run new lines to stove and furnace - Excavate a trench from the gas meter to the wall. - Install polyethylene (PE) pipe and code-compliant riser on both the meter and house sides. - Install black iron pipe along the wall, approximately 20 feet, leading to the laundry room. - Penetrate the wall and route piping into the laundry room. - Extend the pipe within the laundry room along the wall to the existing pipe location. - Ensure that all exposed piping is strapped and supported in accordance with code requirements. - Straighten existing piping as necessary to facilitate connection to the new pipe. - Provide support for existing piping as required. - If the furnace is found to be out of code, install a new sediment trap and new gas flex line. - Conduct pressure tests on both the new and existing piping.

Permit Reviews

Permit Number - TC-RES-0926-05227
Permit Status: Issued
Permit Description: REV1_Additional Gas piping Installation. Abandon existing piping and run new lines to stove and furnace - Excavate a trench from the gas meter to the wall. - Install polyethylene (PE) pipe and code-compliant riser on both the meter and house sides. - Install black iron pipe along the wall, approximately 20 feet, leading to the laundry room. - Penetrate the wall and route piping into the laundry room. - Extend the pipe within the laundry room along the wall to the existing pipe location. - Ensure that all exposed piping is strapped and supported in accordance with code requirements. - Straighten existing piping as necessary to facilitate connection to the new pipe. - Provide support for existing piping as required. - If the furnace is found to be out of code, install a new sediment trap and new gas flex line. - Conduct pressure tests on both the new and existing piping.
Start Date Submittal Complete Date Status  
10/01/2026 RESIDENTIAL SIMPLE REVIEW REVISION v.1 10/01/2026 APPROVED Review Details
09/18/2026 RESIDENTIAL SIMPLE REVIEW v.1 09/18/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0926-05227
Permit Status: Issued
Permit Description: REV1_Additional Gas piping Installation. Abandon existing piping and run new lines to stove and furnace - Excavate a trench from the gas meter to the wall. - Install polyethylene (PE) pipe and code-compliant riser on both the meter and house sides. - Install black iron pipe along the wall, approximately 20 feet, leading to the laundry room. - Penetrate the wall and route piping into the laundry room. - Extend the pipe within the laundry room along the wall to the existing pipe location. - Ensure that all exposed piping is strapped and supported in accordance with code requirements. - Straighten existing piping as necessary to facilitate connection to the new pipe. - Provide support for existing piping as required. - If the furnace is found to be out of code, install a new sediment trap and new gas flex line. - Conduct pressure tests on both the new and existing piping.
Date Description Comments
09/18/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
3538 E 23RD_2_V1.PDF DOCUMENTS VIEW
3538 E 23RD_CO1-2026-10-01_V1.PDF DOCUMENTS VIEW
3538 E 23RD ST_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW