Permit: TC-RES-0926-05150
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
8250 E KORALEE PL
Address NEW:
8250 E KORALEE PL
Apply Date:
09/16/2026
Applicant:
Elton Cross
Description:
Whole home water line replacement. 1"-inch copper insulated main run over roof. 3/4" and half inch pex and copper inside will be run to all fixtures. All copper will be type L hard copper.
Permit Reviews
Permit Number - TC-RES-0926-05150
Permit Status: Complete
Permit Description: Whole home water line replacement. 1"-inch copper insulated main run over roof. 3/4" and half inch pex and copper inside will be run to all fixtures. All copper will be type L hard copper.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/16/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0926-05150
Permit Status: Complete
Permit Description: Whole home water line replacement. 1"-inch copper insulated main run over roof. 3/4" and half inch pex and copper inside will be run to all fixtures. All copper will be type L hard copper.
| Date | Description | Comments |
|---|---|---|
| 09/16/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0926-05150
Permit Description: Whole home water line replacement. 1"-inch copper insulated main run over roof. 3/4" and half inch pex and copper inside will be run to all fixtures. All copper will be type L hard copper.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2026 | COT - RSPL - Plumbing Final | Passed | 09/22/2026 All copper and PEX lines interior holding under test and braced. |
|
| 09/22/2026 | COT - RSPL - Rough Soil | Passed | ||
| 09/22/2026 | COT - RSPL - Yard Water Line | Passed | 09/22/2026 Verified main line holding under test, PRV added. |
|
| 09/22/2026 | RSPL - Plumbing Progress | Passed |