Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Needs Resubmittal
Type:
Residential Building - One or Two Family
Address:
5632 E MABEL ST
Address NEW:
5632 E MABEL ST
Apply Date:
09/15/2026
Applicant:
James Harper
Description:
Install new branch circuits from new upgraded 200 amp panel. to serve an 18 kw water Bosch Tronic 6100 space C electric tankless water heater and electrical range. water heater requires 3 dedicated 240 v, 30 amp circuits. install 1 dedicated 240v, 50 amp circuit for electrical range. New conductors to be installed in EMT raceways approximately 75' including required junctions/pull boxes, fittings, grounding, over current protection, and terminations. all work to comply with applicable electric codes and manufacturer requirements

Permit Reviews

Permit Number - TC-RES-0926-05144
Permit Status: Needs resubmittal
Permit Description: Install new branch circuits from new upgraded 200 amp panel. to serve an 18 kw water Bosch Tronic 6100 space C electric tankless water heater and electrical range. water heater requires 3 dedicated 240 v, 30 amp circuits. install 1 dedicated 240v, 50 amp circuit for electrical range. New conductors to be installed in EMT raceways approximately 75' including required junctions/pull boxes, fittings, grounding, over current protection, and terminations. all work to comply with applicable electric codes and manufacturer requirements
Start Date Submittal Complete Date Status  
09/15/2026 RESIDENTIAL SIMPLE REVIEW v.1 N/A REQUIRES RESUBMIT Review Details