Description:
Replacing water heater. Total developed length is 30 ft, 1 inch gas line enters home and there are 1/2 in lines to both appliances. Both 1/2 in gas lines are approx. 10 ft. Water heater and furnace located in garage. All piping is black iron. Total BTU - 116,000 Water heater - 36,000 Furnace - 80,000

Permit Reviews

Permit Number - TC-RES-0926-05126
Permit Status: Complete
Permit Description: Replacing water heater. Total developed length is 30 ft, 1 inch gas line enters home and there are 1/2 in lines to both appliances. Both 1/2 in gas lines are approx. 10 ft. Water heater and furnace located in garage. All piping is black iron. Total BTU - 116,000 Water heater - 36,000 Furnace - 80,000
Start Date Submittal Complete Date Status  
09/15/2026 RESIDENTIAL SIMPLE REVIEW v.1 09/16/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0926-05126
Permit Status: Complete
Permit Description: Replacing water heater. Total developed length is 30 ft, 1 inch gas line enters home and there are 1/2 in lines to both appliances. Both 1/2 in gas lines are approx. 10 ft. Water heater and furnace located in garage. All piping is black iron. Total BTU - 116,000 Water heater - 36,000 Furnace - 80,000
Date Description Comments
09/16/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0926-05126
Permite Description: Replacing water heater. Total developed length is 30 ft, 1 inch gas line enters home and there are 1/2 in lines to both appliances. Both 1/2 in gas lines are approx. 10 ft. Water heater and furnace located in garage. All piping is black iron. Total BTU - 116,000 Water heater - 36,000 Furnace - 80,000
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/22/2026 COT - BULD - SWG Clearance N/A Not Applicable
09/22/2026 COT - RSPL - Rough Soil N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0926-05126
Permit Description: Replacing water heater. Total developed length is 30 ft, 1 inch gas line enters home and there are 1/2 in lines to both appliances. Both 1/2 in gas lines are approx. 10 ft. Water heater and furnace located in garage. All piping is black iron. Total BTU - 116,000 Water heater - 36,000 Furnace - 80,000
Total Completed Inspections - 1
Date Description Inspector Results Comments
09/22/2026 COT - RSPL - Plumbing Final Passed 09/22/2026
Gas-fired water heater per plan in garage. Verified t&p valve, flue, shutoff valve and fittings.