Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address NEW:
490 S EDGESIDE AV
Apply Date:
09/03/2026
Applicant:
TFS Solar
Description:
Roof mount 10.44 kW DC photovoltaic solar system; 24 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 3 strings. 1 battery expansion pack, (no inverter); 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. 125A subpanel on 60A breaker to move home circuits.

Permit Reviews

Permit Number - TC-RES-0926-04954
Permit Status: Issued
Permit Description: Roof mount 10.44 kW DC photovoltaic solar system; 24 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 3 strings. 1 battery expansion pack, (no inverter); 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. 125A subpanel on 60A breaker to move home circuits.
Start Date Submittal Complete Date Status  
09/03/2026 RESIDENTIAL SOLAR v.1 09/11/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0926-04954
Permit Status: Issued
Permit Description: Roof mount 10.44 kW DC photovoltaic solar system; 24 modules; 27 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 3 strings. 1 battery expansion pack, (no inverter); 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. 125A subpanel on 60A breaker to move home circuits.
Date Description Comments
09/11/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-KEEME CHARLES PV STORAGE - DRAWINGS-490-EDGESIDE-AV_V1.PDF DOCUMENTS VIEW
KEEME CHARLES PV STORAGE - SPECS_V1.PDF DOCUMENTS VIEW