Permit Details

Status:
Withdrawn
Type:
Residential Building - One or Two Family
Address:
9330 E 27TH ST
Address NEW:
9330 E 27TH ST
Apply Date:
09/17/2025
Applicant:
Stephen Jobe
Description:
-Trench from meter to home, under one wall (or thru with sleeve) approx 65 feet, 13-16” down -Disconnect all connections servicing furnace and water heater -Remove piping as much as possible -Remove and drain water heater from closet -Install new 1” PE gasline under ground with (2) 1” 30x PE Risers with prep guard installed per code. -yellow tracer wire to be laid in the trench Per code requirement -from house riser, install a 1” ball valve and reducer coupling (not bushing) to 3/4”. -run 3/4” black iron piping up and through the bird box on the east side of the home -run black iron gas piping through to back line of furnace closet and route gas to behind the units -install proper tee and isolation for each unit. Pressure test system at meter

Permit Reviews

Permit Number - TC-RES-0925-04599
Permit Status: Withdrawn
Permit Description: -Trench from meter to home, under one wall (or thru with sleeve) approx 65 feet, 13-16” down -Disconnect all connections servicing furnace and water heater -Remove piping as much as possible -Remove and drain water heater from closet -Install new 1” PE gasline under ground with (2) 1” 30x PE Risers with prep guard installed per code. -yellow tracer wire to be laid in the trench Per code requirement -from house riser, install a 1” ball valve and reducer coupling (not bushing) to 3/4”. -run 3/4” black iron piping up and through the bird box on the east side of the home -run black iron gas piping through to back line of furnace closet and route gas to behind the units -install proper tee and isolation for each unit. Pressure test system at meter
Start Date Submittal Complete Date Status  
09/17/2025 RESIDENTIAL SIMPLE REVIEW v.1 09/18/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0925-04599
Permit Status: Withdrawn
Permit Description: -Trench from meter to home, under one wall (or thru with sleeve) approx 65 feet, 13-16” down -Disconnect all connections servicing furnace and water heater -Remove piping as much as possible -Remove and drain water heater from closet -Install new 1” PE gasline under ground with (2) 1” 30x PE Risers with prep guard installed per code. -yellow tracer wire to be laid in the trench Per code requirement -from house riser, install a 1” ball valve and reducer coupling (not bushing) to 3/4”. -run 3/4” black iron piping up and through the bird box on the east side of the home -run black iron gas piping through to back line of furnace closet and route gas to behind the units -install proper tee and isolation for each unit. Pressure test system at meter
Date Description Comments
09/17/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Documents

File Name Document Type  
9330 E. 27TH GASLINE PERMIT_V1.PDF DOCUMENTS VIEW