Permit: TC-RES-0924-05494
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3543 N SANTA RITA AV
Address NEW:
3543 N SANTA RITA AV
Apply Date:
09/23/2024
Applicant:
Albert Acosta
Description:
We will be running a new gas line. A total of 100ft of black iron pipe. We will be running the gas line through the attic and connecting to furnace, water heater and dryer. Line to furnace will be 1" and line to water heater and dryer will be 1/2". 100,000 BTU Furnace 25,000 BTU Dryer 40,000 BTU Water Heater
Permit Reviews
Permit Number - TC-RES-0924-05494
Permit Status: Complete
Permit Description: We will be running a new gas line. A total of 100ft of black iron pipe. We will be running the gas line through the attic and connecting to furnace, water heater and dryer. Line to furnace will be 1" and line to water heater and dryer will be 1/2".
100,000 BTU Furnace
25,000 BTU Dryer
40,000 BTU Water Heater
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/23/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/23/2024 | REQUIRES RESUBMIT |
| 09/24/2024 | RESIDENTIAL SIMPLE REVIEW v.2 | 09/24/2024 | APPROVED |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0924-05494
Permit Description: We will be running a new gas line. A total of 100ft of black iron pipe. We will be running the gas line through the attic and connecting to furnace, water heater and dryer. Line to furnace will be 1" and line to water heater and dryer will be 1/2".
100,000 BTU Furnace
25,000 BTU Dryer
40,000 BTU Water Heater
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 10/02/2024 | COT - BULD - SWG Clearance | Passed | Approved gas piping and pressure test - SWG Clearance is required for the reconnection |