Permit: TC-RES-0924-05314
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2503 E MENOR SV
Address NEW:
2503 E MENOR SV
Apply Date:
09/12/2024
Applicant:
Jeff Heisler
Description:
(1) 3.5 ton condenser in back yard changeout like for like (1) 3.5 indoor coil changeout (1) 80K BTUS furnace in closet changeout like for like
Permit Reviews
Permit Number - TC-RES-0924-05314
Permit Status: Inspections
Permit Description: (1) 3.5 ton condenser in back yard changeout like for like
(1) 3.5 indoor coil changeout
(1) 80K BTUS furnace in closet changeout like for like
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/13/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/16/2024 | APPROVED |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0924-05314
Permite Description: (1) 3.5 ton condenser in back yard changeout like for like
(1) 3.5 indoor coil changeout
(1) 80K BTUS furnace in closet changeout like for like
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2024 | RSME - Mechanical Progress | N/A | Re-inspection required | 10/7/24: refrigerant lines must be insulated and UV protected, tape must be removed at double wall pipe at b-vent. condensate pump shall not be wired into furnace. |