Permit: TC-RES-0924-05153
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
6334 N VUELTA TAJO
Address NEW:
6334 N VUELTA TAJO
Apply Date:
09/06/2024
Applicant:
Kyle Zimmermann
Description:
-Remove existing interior Federal Pacific sub-panel in garage area due to no UL list ring and out of code. Supply and install (1) Cutler Hammer 125amp-220volt flush mount sub-panel at existing location. Install existing aluminum feeder cables to new main lugs. Install (1) ground bar. Install existing branch circuitry neutral wiring to neutral bar. Install existing branch circuitry ground wiring to ground bar. Install new breakers for all existing circuits to include (1) 50amp-220 volt, (4) 30amp-220volt, (1) 20amp-220volt, (3) 20amp-110volt, and (5) 15amp-110volt Cutler Hammer circuit breakers. Install deoxidizing agent at all aluminum wire terminations. Power test system.
Permit Reviews
Permit Number - TC-RES-0924-05153
Permit Status: Expired
Permit Description: -Remove existing interior Federal Pacific sub-panel in garage area due to no UL list ring and out of code. Supply and install (1) Cutler Hammer 125amp-220volt flush mount sub-panel at existing location. Install existing aluminum feeder cables to new main lugs.
Install (1) ground bar. Install existing branch circuitry neutral wiring to neutral bar. Install existing branch circuitry ground wiring to ground bar. Install new breakers for all existing circuits to include (1) 50amp-220 volt, (4) 30amp-220volt, (1) 20amp-220volt, (3)
20amp-110volt, and (5) 15amp-110volt Cutler Hammer circuit breakers. Install deoxidizing agent at all aluminum wire terminations.
Power test system.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/09/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/09/2024 | REQUIRES RESUBMIT |