Permit: TC-RES-0924-05081
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3536 S RANDI PL
Address NEW:
3536 S RANDI PL
Apply Date:
09/03/2024
Applicant:
Gregory Chaisson
Description:
Demo 200 amp fpe loadcenter and meter, install a 200 amp main breaker panel with new meter can, drive 2 new ground rods for grounding, bond the water line there is no gas lines
Permit Reviews
Permit Number - TC-RES-0924-05081
Permit Status: Inspections
Permit Description: Demo 200 amp fpe loadcenter and meter, install a 200 amp main breaker panel with new meter can, drive 2 new ground rods for grounding, bond the water line there is no gas lines
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/03/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/03/2024 | APPROVED |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0924-05081
Permit Description: Demo 200 amp fpe loadcenter and meter, install a 200 amp main breaker panel with new meter can, drive 2 new ground rods for grounding, bond the water line there is no gas lines
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2024 | BULD - Electrical Clearance | Passed | Approved 200A service panel upgrade - INCR Clearance was called into TEP at 11:25am | |
| 10/01/2024 | COT - RSEL - Electrical Final | Passed |