Permit Details

Status:
Withdrawn
Type:
Residential Building - One or Two Family
Address:
7611 E SENECA ST
Address NEW:
7611 E SENECA ST
Apply Date:
09/04/2023
Applicant:
Gregory Chaisson
Description:
Demo the old ITE loadcenter and meter can, drive 2 new 5/8 inch grounding rods, and install new 200 amp main breaker nema 3r loadcenter with a new tep approved meter can. Run #4 bare copper to both grounding rods to the ground bar in the 200 amp loadcenter, then run #6 bare copper to the water/gas lines. I will cut the existing .5 inch pvc down then add a nema 3r single gang jbox to rerun with .5 inch emt to the 200 amp loadcenter. I will add all correct appropriate size overcurrent protection devices (breakers).

Permit Reviews

Permit Number - TC-RES-0923-07748
Permit Status: Withdrawn
Permit Description: Demo the old ITE loadcenter and meter can, drive 2 new 5/8 inch grounding rods, and install new 200 amp main breaker nema 3r loadcenter with a new tep approved meter can. Run #4 bare copper to both grounding rods to the ground bar in the 200 amp loadcenter, then run #6 bare copper to the water/gas lines. I will cut the existing .5 inch pvc down then add a nema 3r single gang jbox to rerun with .5 inch emt to the 200 amp loadcenter. I will add all correct appropriate size overcurrent protection devices (breakers).
Start Date Submittal Complete Date Status  
09/05/2023 RESIDENTIAL SIMPLE REVIEW v.1 09/06/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0923-07748
Permit Status: Withdrawn
Permit Description: Demo the old ITE loadcenter and meter can, drive 2 new 5/8 inch grounding rods, and install new 200 amp main breaker nema 3r loadcenter with a new tep approved meter can. Run #4 bare copper to both grounding rods to the ground bar in the 200 amp loadcenter, then run #6 bare copper to the water/gas lines. I will cut the existing .5 inch pvc down then add a nema 3r single gang jbox to rerun with .5 inch emt to the 200 amp loadcenter. I will add all correct appropriate size overcurrent protection devices (breakers).
Date Description Comments
09/05/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Completed Inspections

Permit Status: Withdrawn
Permit Number: TC-RES-0923-07748
Permit Description: Demo the old ITE loadcenter and meter can, drive 2 new 5/8 inch grounding rods, and install new 200 amp main breaker nema 3r loadcenter with a new tep approved meter can. Run #4 bare copper to both grounding rods to the ground bar in the 200 amp loadcenter, then run #6 bare copper to the water/gas lines. I will cut the existing .5 inch pvc down then add a nema 3r single gang jbox to rerun with .5 inch emt to the 200 amp loadcenter. I will add all correct appropriate size overcurrent protection devices (breakers).
Total Completed Inspections - 2
Date Description Inspector Results Comments
10/17/2023 COT - RSEL - Electrical Final Passed
10/17/2023 BULD - Electrical Clearance Passed Approved service panel upgrade, INCR Clearance was called into TEP at 11:20am