Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
10351 E CAMINO QUINCE
Apply Date:
08/31/2026
Applicant:
Kyle Zimmermann
Description:
-Upgrade main electrical service due to age and condition. Remove existing Federal Pacific load center. Remove existing meter base. -Install (1) 200amp-220volt Milbank meter base. Install (1) 200amp-220volt Eaton Cutler Hammer 30 space main breaker load center. Install new TEP feeder cables. -Intercept existing conduits and wiring and properly install into new service. Install all existing branch circuitry into new load center. Properly terminate all ground and nuetral wiring. Install new breakers for all existing circuitry to include (2) 50amp-220volt, (3) 30amp-220volt, (14) 20amp-110volt, and (4) 15amp-110volt Eaton Cutler Hammer circuit breakers. -Install (1) grounding system to include (2) ground rods bonded to gas and water. -Install (1) Eaton Cutler Hammer ULTRA2 home surge protector on main electrical service. Install (1) Eaton Cutler Hammer 50amp-220volt circuit breaker to operate new device. New surge protector covers up to $75,000 in electrical components in the event that the new device does not dissipate the surge.

Permit Reviews

Permit Number - TC-RES-0826-04893
Permit Status: Inspections
Permit Description: -Upgrade main electrical service due to age and condition. Remove existing Federal Pacific load center. Remove existing meter base. -Install (1) 200amp-220volt Milbank meter base. Install (1) 200amp-220volt Eaton Cutler Hammer 30 space main breaker load center. Install new TEP feeder cables. -Intercept existing conduits and wiring and properly install into new service. Install all existing branch circuitry into new load center. Properly terminate all ground and nuetral wiring. Install new breakers for all existing circuitry to include (2) 50amp-220volt, (3) 30amp-220volt, (14) 20amp-110volt, and (4) 15amp-110volt Eaton Cutler Hammer circuit breakers. -Install (1) grounding system to include (2) ground rods bonded to gas and water. -Install (1) Eaton Cutler Hammer ULTRA2 home surge protector on main electrical service. Install (1) Eaton Cutler Hammer 50amp-220volt circuit breaker to operate new device. New surge protector covers up to $75,000 in electrical components in the event that the new device does not dissipate the surge.
Start Date Submittal Complete Date Status  
09/01/2026 RESIDENTIAL SIMPLE REVIEW v.1 09/02/2026 REQUIRES RESUBMIT Review Details
09/03/2026 RESIDENTIAL SIMPLE REVIEW v.2 09/03/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0826-04893
Permit Status: Inspections
Permit Description: -Upgrade main electrical service due to age and condition. Remove existing Federal Pacific load center. Remove existing meter base. -Install (1) 200amp-220volt Milbank meter base. Install (1) 200amp-220volt Eaton Cutler Hammer 30 space main breaker load center. Install new TEP feeder cables. -Intercept existing conduits and wiring and properly install into new service. Install all existing branch circuitry into new load center. Properly terminate all ground and nuetral wiring. Install new breakers for all existing circuitry to include (2) 50amp-220volt, (3) 30amp-220volt, (14) 20amp-110volt, and (4) 15amp-110volt Eaton Cutler Hammer circuit breakers. -Install (1) grounding system to include (2) ground rods bonded to gas and water. -Install (1) Eaton Cutler Hammer ULTRA2 home surge protector on main electrical service. Install (1) Eaton Cutler Hammer 50amp-220volt circuit breaker to operate new device. New surge protector covers up to $75,000 in electrical components in the event that the new device does not dissipate the surge.
Date Description Comments
09/03/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0826-04893
Permit Description: -Upgrade main electrical service due to age and condition. Remove existing Federal Pacific load center. Remove existing meter base. -Install (1) 200amp-220volt Milbank meter base. Install (1) 200amp-220volt Eaton Cutler Hammer 30 space main breaker load center. Install new TEP feeder cables. -Intercept existing conduits and wiring and properly install into new service. Install all existing branch circuitry into new load center. Properly terminate all ground and nuetral wiring. Install new breakers for all existing circuitry to include (2) 50amp-220volt, (3) 30amp-220volt, (14) 20amp-110volt, and (4) 15amp-110volt Eaton Cutler Hammer circuit breakers. -Install (1) grounding system to include (2) ground rods bonded to gas and water. -Install (1) Eaton Cutler Hammer ULTRA2 home surge protector on main electrical service. Install (1) Eaton Cutler Hammer 50amp-220volt circuit breaker to operate new device. New surge protector covers up to $75,000 in electrical components in the event that the new device does not dissipate the surge.
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/30/2026 BULD - Electrical Clearance Passed TEP CLEARANCE: INCR, called in at 9:38.
09/30/2026 COT - RSEL - Electrical Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
10351 N CAMINO QUINCE SITE MAP_V1.PDF DOCUMENTS VIEW
SURGE PROTECTION-C1_V1.PDF DOCUMENTS VIEW