Permit: TC-RES-0826-04837
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
6613 E CALLE DE SAN ALBERTO
Address NEW:
6613 E CALLE DE SAN ALBERTO
Apply Date:
08/28/2026
Applicant:
brian dunn
Description:
The residents currently has a 40 gallon gas water heater from 1991. We are replacing it with a new 40 gallon gas water heater installed with pan and updated gas valve, as it had a plug valve before. Twenty-eight feet of 3/4 gas line runs from meter to mechanical room. It stubs out 3/4 and tee's off 1/2 to water heater and furnace.
Permit Reviews
Permit Number - TC-RES-0826-04837
Permit Status: Complete
Permit Description: The residents currently has a 40 gallon gas water heater from 1991. We are replacing it with a new 40 gallon gas water heater installed with pan and updated gas valve, as it had a plug valve before. Twenty-eight feet of 3/4 gas line runs from meter to mechanical room. It stubs out 3/4 and tee's off 1/2 to water heater and furnace.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2026 | RESIDENTIAL SIMPLE REVIEW v.2 | 09/16/2026 | APPROVED |
| 08/28/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 08/28/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0826-04837
Permit Status: Complete
Permit Description: The residents currently has a 40 gallon gas water heater from 1991. We are replacing it with a new 40 gallon gas water heater installed with pan and updated gas valve, as it had a plug valve before. Twenty-eight feet of 3/4 gas line runs from meter to mechanical room. It stubs out 3/4 and tee's off 1/2 to water heater and furnace.
| Date | Description | Comments |
|---|---|---|
| 09/16/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0826-04837
Permit Description: The residents currently has a 40 gallon gas water heater from 1991. We are replacing it with a new 40 gallon gas water heater installed with pan and updated gas valve, as it had a plug valve before. Twenty-eight feet of 3/4 gas line runs from meter to mechanical room. It stubs out 3/4 and tee's off 1/2 to water heater and furnace.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2026 | COT - RSPL - Plumbing Final | Passed | 09/23/2026 Approved per plan. All water line secured and holding under test. Added foam to 3/4" hot lines. Moved T&P valve per manufacture's specification. |