Permit: TC-RES-0826-04401
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
9565 E MEOLA DR
Address NEW:
9565 E MEOLA DR
Apply Date:
08/10/2026
Applicant:
Project Manager
Description:
Installation of roof-mounted PV SYSTEM SIZE: DC SIZE : 20 X 405W=8.100 kW DC; AC SIZE : 1 X 11500W=11.500 kW AC; (20) LONGI LR5-54HPB-405M (405W) [BLK] MODULES; (1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M); (1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
Permit Reviews
Permit Number - TC-RES-0826-04401
Permit Status: Complete
Permit Description: Installation of roof-mounted PV SYSTEM SIZE: DC SIZE : 20 X 405W=8.100 kW DC;
AC SIZE : 1 X 11500W=11.500 kW AC;
(20) LONGI LR5-54HPB-405M (405W) [BLK] MODULES;
(1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M);
(1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/10/2026 | RESIDENTIAL SOLAR v.1 | 08/21/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0826-04401
Permit Status: Complete
Permit Description: Installation of roof-mounted PV SYSTEM SIZE: DC SIZE : 20 X 405W=8.100 kW DC;
AC SIZE : 1 X 11500W=11.500 kW AC;
(20) LONGI LR5-54HPB-405M (405W) [BLK] MODULES;
(1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M);
(1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
| Date | Description | Comments |
|---|---|---|
| 08/21/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0826-04401
Permite Description: Installation of roof-mounted PV SYSTEM SIZE: DC SIZE : 20 X 405W=8.100 kW DC;
AC SIZE : 1 X 11500W=11.500 kW AC;
(20) LONGI LR5-54HPB-405M (405W) [BLK] MODULES;
(1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M);
(1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0826-04401
Permit Description: Installation of roof-mounted PV SYSTEM SIZE: DC SIZE : 20 X 405W=8.100 kW DC;
AC SIZE : 1 X 11500W=11.500 kW AC;
(20) LONGI LR5-54HPB-405M (405W) [BLK] MODULES;
(1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M);
(1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2026 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/17/2026 | BULD - Electrical Clearance | Passed |