Permit: TC-RES-0825-04096
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
375 N LONGFELLOW AV
Address NEW:
375 N LONGFELLOW AV
Apply Date:
08/19/2025
Applicant:
TFS Solar
Description:
Roof mount 5.7 kW DC addition to existing photovoltaic solar system (new total system size: 12.54 kW). 13 additional modules with rapid shutdown added to (2) existing Powerwall-3 batteries (1 branch to each). 200A bus with 200A MCB.
Permit Reviews
Permit Number - TC-RES-0825-04096
Permit Status: Complete
Permit Description: Roof mount 5.7 kW DC addition to existing photovoltaic solar system (new total system size: 12.54 kW). 13 additional modules with rapid shutdown added to (2) existing Powerwall-3 batteries (1 branch to each). 200A bus with 200A MCB.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/19/2025 | RESIDENTIAL SOLAR v.1 | 09/17/2025 | APPROVED |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0825-04096
Permit Description: Roof mount 5.7 kW DC addition to existing photovoltaic solar system (new total system size: 12.54 kW). 13 additional modules with rapid shutdown added to (2) existing Powerwall-3 batteries (1 branch to each). 200A bus with 200A MCB.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2025 | RSBU - Building Final | Passed | ||
| 10/13/2025 | COT - RSOL - Electrical Final Solar Project | Passed | ||
| 10/14/2025 | BULD - Electrical Clearance | Passed | 10.14.2025 Clearance to TEP DGC/BAT for prior inspection. DG meter currently set, scope of work added 13 panels to existing system. |