Permit: TC-RES-0825-03795
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
3619 S SANTEE AV
Address NEW:
3619 S SANTEE AV
Apply Date:
08/01/2025
Applicant:
Lee Transue
Description:
Fire Damage Repair - Replace Garage and Dwelling Roof
Permit Reviews
Permit Number - TC-RES-0825-03795
Permit Status: Issued
Permit Description: Fire Damage Repair - Replace Garage and Dwelling Roof
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/01/2025 | RESIDENTIAL ADD/ALT v.1 | 08/29/2025 | APPROVED |
| 09/11/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/12/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0825-03795
Permit Status: Issued
Permit Description: Fire Damage Repair - Replace Garage and Dwelling Roof
| Date | Description | Comments |
|---|---|---|
| 08/01/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 08/21/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-RES-0825-03795
Permite Description: Fire Damage Repair - Replace Garage and Dwelling Roof
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2025 | COT - RSPL - Rough Soil | N/A | Not Ready | |
| 11/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | Nailing at edges not per schedule |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-0825-03795
Permit Description: Fire Damage Repair - Replace Garage and Dwelling Roof
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2025 | COT - RSBU - Preslab | Passed | 9.12.25 Approved |
|
| 11/03/2025 | COT - RSBU - Roof Nailing | Passed | Passed 11/3/25 | |
| 11/04/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Passed 11/4/25 |