Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
138 E 14TH ST
Address NEW:
138 E 14TH ST
Apply Date:
08/13/2024
Applicant:
Richard Hendricks
Description:
Recover Roof and Replace Damaged Sheathing - CE-VIO0724-02978

Permit Reviews

Permit Number - TC-RES-0824-04734
Permit Status: Inspections
Permit Description: Recover Roof and Replace Damaged Sheathing - CE-VIO0724-02978
Start Date Submittal Complete Date Status  
08/14/2024 RESIDENTIAL NEW DWELLING v.2 09/17/2024 REQUIRES RESUBMIT Review Details
08/14/2024 RESIDENTIAL NEW DWELLING v.1 08/14/2024 REQUIRES RESUBMIT Review Details
12/14/2024 RESIDENTIAL NEW DWELLING v.5 01/13/2025 REQUIRES RESUBMIT Review Details
11/06/2024 RESIDENTIAL NEW DWELLING v.3 11/06/2024 REQUIRES RESUBMIT Review Details
01/13/2025 RESIDENTIAL NEW DWELLING v.6 01/14/2025 APPROVED Review Details
11/18/2024 RESIDENTIAL NEW DWELLING v.4 11/19/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0824-04734
Permit Status: Inspections
Permit Description: Recover Roof and Replace Damaged Sheathing - CE-VIO0724-02978
Date Description Comments
12/14/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0824-04734
Permite Description: Recover Roof and Replace Damaged Sheathing - CE-VIO0724-02978
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/12/2025 COT - RSBU - Roof Nailing N/A Re-inspection required Sheathing has been installed without verification of nailing pattern. Provide letter stating full responsibility of roof sheathing being correct size along with nailing per schedule. 8/12/2025
08/12/2025 RSBU - Building Final N/A Not Ready Not ready. Provide proper flashing at all chimneys and penetrations. Provide rake metal at all edges of roof. Provide roof jacks along with boots at all pipes. Provide roof to wall metal. All need to be properly sealed with flashing materials. 8/12/2025

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW