Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0823-07233
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2303 W HELTON LN
Address NEW:
2303 W HELTON LN
Apply Date:
08/10/2023
Applicant:
Luis Luna
Description:
Bedroom and Bath Addition
Permit Reviews
Permit Number - TC-RES-0823-07233
Permit Status: Inspections
Permit Description: Bedroom and Bath Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/18/2023 | RESIDENTIAL NEW DWELLING v.1 | 08/21/2023 | REQUIRES RESUBMIT |
| 09/16/2024 | RESIDENTIAL NEW DWELLING v.1 | 09/19/2024 | APPROVED |
| 09/28/2023 | RESIDENTIAL NEW DWELLING v.2 | 10/19/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0823-07233
Permit Status: Inspections
Permit Description: Bedroom and Bath Addition
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/13/2024 |
Conditions
Permit Number - TC-RES-0823-07233
Permit Status: Inspections
Permit Description: Bedroom and Bath Addition
| Date | Description | Comments |
|---|---|---|
| 10/19/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/13/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0823-07233
Permite Description: Bedroom and Bath Addition
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2024 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 6/26/24: dowels from new footing at proposed addition to existing footing missing per plan. (Plans call for (2) #4) 6/27/24: corrections made at footing around perimeter of addition. Ok to place concrete in footing. |
| 08/09/2024 | COT - RSBU - Preslab | N/A | Re-inspection required | 8/9/24: new concrete slab shall be key'd to existing CMU wall with #4 rebar dowels at 16" O.C with penetration 6" into both directions (not per plan missing dowels). |
| 02/04/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Canceled | 2/4/25 canceled by contractor |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0823-07233
Permit Description: Bedroom and Bath Addition
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2024 | COT - RSPL - Rough Soil | Passed | Canceled per contractor. 6/21/2024 7/30/24: fully expose underground plumbing to verify proper installation, multiple wet spots (possible leak), test stack not full. NOT READY 8/1/24: corrections made ok to backfill. Shading required |
|
| 08/16/2024 | COT - RSBU - Preslab | Passed | ||
| 08/28/2024 | COT - RSBU - Masonry Pregrout | Passed | 7/12/24: Stem-wall reinforcement per plan ok to proceed with grout at progress areas. 8/16/24: reinforcement at first lift per plans ok to proceed. 8/28/24: top out reinforcement per plan ok to grout. |
|
| 02/04/2025 | COT - RSBU - Roof Nailing | Passed | 2/4/25 roof nailing is per schedule ok to proceed. | |
| 02/26/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 2/26/25 corrections made |