Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
853 W FLORENCE ST
Apply Date:
07/30/2026
Applicant:
Hector Alvarez
Description:
Replace main gas service line from meter to home. 35 feet from meter to home riser. Then 45 feet from riser to furthest fixture. replacing all pipe under manufactured home to feed 3 fixtures. Water heater, Furnace and Range. with a total of 165,000 BTUS. Pipe under ground would be (PE) Polyethylene ran in 1 inch with AWE 18 gauge yellow tracer wire. And from riser at home material would be Black Iron in 1 inch and will reduce to 3/4 at fixtures. all pipe will be strapped and secured. REV1: Dryer added with a total of 205,000 BTUS

Permit Reviews

Permit Number - TC-RES-0726-04235
Permit Status: Complete
Permit Description: Replace main gas service line from meter to home. 35 feet from meter to home riser. Then 45 feet from riser to furthest fixture. replacing all pipe under manufactured home to feed 3 fixtures. Water heater, Furnace and Range. with a total of 165,000 BTUS. Pipe under ground would be (PE) Polyethylene ran in 1 inch with AWE 18 gauge yellow tracer wire. And from riser at home material would be Black Iron in 1 inch and will reduce to 3/4 at fixtures. all pipe will be strapped and secured. REV1: Dryer added with a total of 205,000 BTUS
Start Date Submittal Complete Date Status  
08/03/2026 RESIDENTIAL SIMPLE REVIEW REVISION v.1 08/03/2026 APPROVED Review Details
07/30/2026 RESIDENTIAL SIMPLE REVIEW v.1 07/31/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0726-04235
Permit Status: Complete
Permit Description: Replace main gas service line from meter to home. 35 feet from meter to home riser. Then 45 feet from riser to furthest fixture. replacing all pipe under manufactured home to feed 3 fixtures. Water heater, Furnace and Range. with a total of 165,000 BTUS. Pipe under ground would be (PE) Polyethylene ran in 1 inch with AWE 18 gauge yellow tracer wire. And from riser at home material would be Black Iron in 1 inch and will reduce to 3/4 at fixtures. all pipe will be strapped and secured. REV1: Dryer added with a total of 205,000 BTUS
Date Description Comments
07/31/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0726-04235
Permit Description: Replace main gas service line from meter to home. 35 feet from meter to home riser. Then 45 feet from riser to furthest fixture. replacing all pipe under manufactured home to feed 3 fixtures. Water heater, Furnace and Range. with a total of 165,000 BTUS. Pipe under ground would be (PE) Polyethylene ran in 1 inch with AWE 18 gauge yellow tracer wire. And from riser at home material would be Black Iron in 1 inch and will reduce to 3/4 at fixtures. all pipe will be strapped and secured. REV1: Dryer added with a total of 205,000 BTUS
Total Completed Inspections - 2
Date Description Inspector Results Comments
08/06/2026 COT - RSPL - Plumbing Final Passed Passed CLEARANCE SWG
08/06/2026 COT - BULD - SWG Clearance Passed Passed CLEARANCE SWG