Permit: TC-RES-0726-03754
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3232 E FAIRMOUNT ST
Address NEW:
3232 E FAIRMOUNT ST
Apply Date:
07/09/2026
Applicant:
Andrea Perea
Description:
like for like water repipe, Like for like sewer line replacement, replace waterline
Permit Reviews
Permit Number - TC-RES-0726-03754
Permit Status: Complete
Permit Description: like for like water repipe, Like for like sewer line replacement, replace waterline
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/13/2026 | RESIDENTIAL SIMPLE REVIEW v.2 | 07/13/2026 | APPROVED |
| 07/09/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 07/10/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0726-03754
Permit Status: Complete
Permit Description: like for like water repipe, Like for like sewer line replacement, replace waterline
| Date | Description | Comments |
|---|---|---|
| 07/13/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0726-03754
Permite Description: like for like water repipe, Like for like sewer line replacement, replace waterline
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2026 | COT - RSEL - Grounding/Bonding | N/A | Not Applicable | |
| 07/14/2026 | COT - RSPL - Sewer | N/A | Not Ready | Provide test before backfilling. 7/14/2026 |
| 07/14/2026 | COT - RSPL - Plumbing Final | N/A | Not Ready | Provide a minimum of 12" depth near house at main water line. Secure tracer wire to pipe. Secure every 32" and insulate water lines in crawl space. Provide sleeve for pex lines underneath concrete. 1st bathroom and kitchen sink studs vent need to be above flood line. 7/14/2026 |
| 07/14/2026 | COT - RSPL - Rough Soil | N/A | Not Ready | Provide a minimum of 12" depth near house at main water line. Secure tracer wire to pipe. Secure every 32" and insulate water lines in crawl space. Provide sleeve for pex lines underneath concrete. 1st bathroom and kitchen sink studs vent need to be above flood line. 7/14/2026 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0726-03754
Permit Description: like for like water repipe, Like for like sewer line replacement, replace waterline
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2026 | COT - RSPL - Sewer | Passed | ||
| 07/16/2026 | COT - RSPL - Plumbing Final | Passed | ||
| 07/16/2026 | COT - RSPL - Rough Soil | Passed |