Permit: TC-RES-0726-03737
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2921 E FLORENCE DR
Address NEW:
2921 E FLORENCE DR
Apply Date:
07/08/2026
Applicant:
Jesus Cedeno
Description:
interior alteration, minor
Permit Reviews
Permit Number - TC-RES-0726-03737
Permit Status: Inspections
Permit Description: interior alteration, minor
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/14/2026 | RESIDENTIAL ADD/ALT v.1 | 07/20/2026 | REQUIRES RESUBMIT |
| 09/09/2026 | ADMINISTRATIVE v.2 | N/A | APPROVED |
| 08/27/2026 | RESIDENTIAL ADD/ALT v.3 | 09/01/2026 | APPROVED |
| 07/27/2026 | RESIDENTIAL ADD/ALT v.2 | 07/31/2026 | REQUIRES RESUBMIT |
| 09/01/2026 | ADMINISTRATIVE v.1 | 09/01/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0726-03737
Permit Status: Inspections
Permit Description: interior alteration, minor
| Date | Description | Comments |
|---|---|---|
| 09/01/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 07/20/2026 | Parcel is located within a regulatory floodplain. Engineering review required prior to issuance, floodplain use permit TE-FPU-0726-00300 must pay fees prior to issuance. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0726-03737
Permite Description: interior alteration, minor
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 09/11/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Applicable | |
| 09/11/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Partial Pass | Partial pass items that need to be corrected. The electrical panel is improperly located and a subpanel inside the house in the kitchen area is improperly located please correct items. The gas meter is also going to need to be relocated existing location is less than 3 feet away from windows And electrical meter. The interior remodel requires smoke detectors and high low combustion air for the water heater closet. Recall this inspection after this work is ready to complete on either a new permit or revised plan. OK to proceed with insulation and drywall in the addition area |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0726-03737
Permit Description: interior alteration, minor
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2026 | COT - RSBU - Interior Shear Bracing | Passed | 09/18/2026 Verified drywall nail schedule. Okay to tape and texture. |