Permit: TC-RES-0725-03677
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
4402 E ELMWOOD ST
Address NEW:
4402 E ELMWOOD ST
Apply Date:
07/24/2025
Applicant:
TFS Solar
Description:
13.5 kWh Storage addition to existing PV system. 1 Tesla Powerwall-3 battery with integrated PV inverter. Remove existing inverters and add rapid shutdown devices. All 4 existing strings to be added to Powerwall. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup. Re-use existing pv meter and DG disconnect.
Permit Reviews
Permit Number - TC-RES-0725-03677
Permit Status: Complete
Permit Description: 13.5 kWh Storage addition to existing PV system. 1 Tesla Powerwall-3 battery with integrated PV inverter. Remove existing inverters and add rapid shutdown devices. All 4 existing strings to be added to Powerwall. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Re-use existing pv meter and DG disconnect.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/24/2025 | RESIDENTIAL SOLAR v.1 | 08/21/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0725-03677
Permit Status: Complete
Permit Description: 13.5 kWh Storage addition to existing PV system. 1 Tesla Powerwall-3 battery with integrated PV inverter. Remove existing inverters and add rapid shutdown devices. All 4 existing strings to be added to Powerwall. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Re-use existing pv meter and DG disconnect.
| Date | Description | Comments |
|---|---|---|
| 08/21/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0725-03677
Permit Description: 13.5 kWh Storage addition to existing PV system. 1 Tesla Powerwall-3 battery with integrated PV inverter. Remove existing inverters and add rapid shutdown devices. All 4 existing strings to be added to Powerwall. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Re-use existing pv meter and DG disconnect.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2025 | BULD - Electrical Clearance | Passed | 10.2.2025 Clearance to TEP DGC/BAT. |
|
| 10/02/2025 | COT - RSOL - Electrical Final Solar Project | Passed | ||
| 10/02/2025 | RSBU - Building Final | Passed |