Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Apply Date:
07/15/2025
Applicant:
Bill Clark
Description:
ADU

Permit Reviews

Permit Number - TC-RES-0725-03528
Permit Status: Inspections complete
Permit Description: ADU
Start Date Submittal Complete Date Status  
08/26/2025 RESTAMP - RESIDENTIAL v.1 08/27/2025 APPROVED Review Details
07/16/2025 RESIDENTIAL NEW DWELLING v.1 08/11/2025 REQUIRES RESUBMIT Review Details
10/21/2025 RESIDENTIAL ADU REVISION v.1 11/04/2025 APPROVED Review Details
08/26/2025 RESIDENTIAL NEW DWELLING v.2 08/26/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0725-03528
Permit Status: Inspections complete
Permit Description: ADU
Total Outstanding Activity Conditions - 1
Date Name
08/11/2025

Conditions

Permit Number - TC-RES-0725-03528
Permit Status: Inspections complete
Permit Description: ADU
Date Description Comments
08/11/2025 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0725-03528
Permite Description: ADU
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/23/2025 COT - RSPL - Rough Soil N/A Re-inspection required 1-Northwest corner is 3’ from property line; not 6’ as swoon on plans.
2-Expose all joints in DWV system 360 degrees for inspection.
3-Laundry room is not drain is not present.
4- Kitchenette sink drain is not present.
12/31/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass Partial pass pending vapor barrier install at existing structure, contractor to remove existing T11 and install vapor barrier over osb, take pictures for verification, then reinstall T11 siding. To be verified at intermediate

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0725-03528
Permit Description: ADU
Total Completed Inspections - 14
Date Description Inspector Results Comments
11/13/2025 COT - RSPL - Rough Soil Passed Passed 11/13/25 ok to backfill
11/13/2025 COT - RSPL - Yard Water Line Passed Passed 11/13/25 ok to backfill
11/13/2025 COT - RSEL - Electrical Underground Passed Passed 11/13/25 ok to backfill
11/19/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
11/19/2025 COT - RSBU - Preslab Passed
12/31/2025 COT - RSBU - Roof Nailing Passed Roof passed 12/31/25
01/08/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
01/08/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
01/08/2026 COT - RSBU - Sustainability Passed
02/05/2026 RSBU - Building Final Passed 02/05/2026
Verfied added water hammer arresters at washer, breaker lock at sub panel for electric water heater, anti-siphon device at hose bibb, bolt down air condenser outside and address number outside to unit.
02/05/2026 COT - RSEL - Electrical Final Passed 02/05/2026
Verfied added water hammer arresters at washer, breaker lock at sub panel for electric water heater, anti-siphon device at hose bibb, bolt down air condenser outside and address number outside to unit.
02/05/2026 COT - RSEL - Outdoor Lighting Passed
02/05/2026 COT - RSME - Mechanical Final Passed 02/05/2026
Verfied added water hammer arresters at washer, breaker lock at sub panel for electric water heater, anti-siphon device at hose bibb, bolt down air condenser outside and address number outside to unit.
02/05/2026 COT - RSPL - Plumbing Final Passed 02/05/2026
Verfied added water hammer arresters at washer, breaker lock at sub panel for electric water heater, anti-siphon device at hose bibb, bolt down air condenser outside and address number outside to unit.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CALLE CUERNAVACA REVISION_V1.PDF DOCUMENTS VIEW
REVISION NARRATIVE CUERNAVACA_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-BENEVILLE_V2.PDF DOCUMENTS VIEW