Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
07/24/2024
Applicant:
TFS Solar
Description:
Roof mount 6.82kW DC photovoltaic solar system; 16 AC modules, 2 branches, PV Combiner Box, 40A PV breaker on 200A bus with 200A MCB, NEMA 14-50 outlet

Permit Reviews

Permit Number - TC-RES-0724-04304
Permit Status: Complete
Permit Description: Roof mount 6.82kW DC photovoltaic solar system; 16 AC modules, 2 branches, PV Combiner Box, 40A PV breaker on 200A bus with 200A MCB, NEMA 14-50 outlet
Start Date Submittal Complete Date Status  
07/25/2024 RESIDENTIAL SOLAR v.1 08/27/2024 APPROVED Review Details

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0724-04304
Permit Description: Roof mount 6.82kW DC photovoltaic solar system; 16 AC modules, 2 branches, PV Combiner Box, 40A PV breaker on 200A bus with 200A MCB, NEMA 14-50 outlet
Total Completed Inspections - 4
Date Description Inspector Results Comments
10/15/2024 COT - RSOL - Grounding/Bonding Solar Project Passed
10/15/2024 RSBU - Building Final Passed
10/15/2024 COT - RSOL - Electrical Final Solar Project Passed
10/15/2024 BULD - Electrical Clearance Passed Approved - DGC Clearance to TEP is required for the solar meter

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
ARMOROSO JOHN PV2 6.82KW EV - SPECS_V1.PDF DOCUMENTS VIEW
CONS-AMOROSO JOHN PV2 6.82KW EV-DRAWINGS_V1.PDF DOCUMENTS VIEW