Start Date Submittal Complete Date Status  
07/24/2024 RESIDENTIAL NEW DWELLING v.1 07/24/2024 REQUIRES RESUBMIT Review Details
09/27/2024 RESIDENTIAL NEW DWELLING v.3 10/28/2024 APPROVED Review Details
03/03/2025 RESIDENTIAL ADU v.1 04/03/2025 APPROVED Review Details
07/25/2024 RESIDENTIAL NEW DWELLING v.2 08/27/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0724-04290
Permit Status: Issued
Permit Description: ADU
Total Outstanding Activity Conditions - 1
Date Name
08/01/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0724-04290
Permit Status: Issued
Permit Description: ADU
Date Description Comments
08/01/2024 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
10/28/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0724-04290
Permite Description: ADU
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/19/2025 COT - RSBU - Preslab N/A Partial Pass 2-19-25, rebar layout verified as per approved plans. However, setbacks from unit 1 & unit 2 not per plans. Setback calls for 13ft 6" and was measured at 12ft. 3". Submit a site plan revision for setbacks and proceed construction at own risk. Revisions must be submitted to the city for review and approval prior to issuing C of O.
04/15/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 4/15/25
1. All anchor bolts had loose nuts.
2. Missing anchor bolt within 12" of splice on south wall
3. Shot pins required within 6" of edge sill plate and every 2' after , I have marked with an x circle.
4. Porch framing not per plan; Beam needs to be 6x10.
5. Handicap blocking needed at bathrooms see page S-2 for details.
6. Porch Beam and post caps not per plan.

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0724-04290
Permit Description: ADU
Total Completed Inspections - 4
Date Description Inspector Results Comments
02/04/2025 COT - RSPL - Rough Soil Passed
04/09/2025 COT - RSBU - Preslab Passed 4/9/2025 setbacks have been revised and now per plot plan.
08/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8.26.26
Corrections ,add as requested, beam verified via provided note
Approved
10/15/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-TC-RES-0724-04290D2_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CALCS REV COLLINGS.PDF_V1.PDF DOCUMENTS VIEW
CONS-CONS_732K24_V3_V3.PDF DOCUMENTS VIEW