Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
911 N 6TH AV
Apply Date:
07/03/2023
Applicant:
TFS Solar
Description:
Roof mount 6.15 kW DC photovoltaic solar system; 15 AC modules, 2 branches, PV Combiner Box, 30A PV breaker on 200A bus with 200A MCB, additional 125A bus Subpanel

Permit Reviews

Permit Number - TC-RES-0723-06284
Permit Status: Inspections complete
Permit Description: Roof mount 6.15 kW DC photovoltaic solar system; 15 AC modules, 2 branches, PV Combiner Box, 30A PV breaker on 200A bus with 200A MCB, additional 125A bus Subpanel
Start Date Submittal Complete Date Status  
08/17/2023 RESIDENTIAL SOLAR v.2 08/17/2023 APPROVED Review Details
07/06/2023 RESIDENTIAL SOLAR v.1 08/17/2023 REQUIRES RESUBMIT Review Details

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0723-06284
Permit Description: Roof mount 6.15 kW DC photovoltaic solar system; 15 AC modules, 2 branches, PV Combiner Box, 30A PV breaker on 200A bus with 200A MCB, additional 125A bus Subpanel
Total Completed Inspections - 3
Date Description Inspector Results Comments
11/02/2023 RSBU - Building Final Passed
11/02/2023 COT - RSOL - Electrical Final Solar Project Passed
11/02/2023 BULD - Electrical Clearance Passed Approved, DGC Clearance to TEP is required for the solar meter

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-DRAWINGS-UPDATED_V1.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-HPZ APPROVAL LETTER - UNLOCK_V1.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-SPECS_V1.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-DRAWINGS-UPDATED_V1.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-HPZ APPROVAL LETTER - UNLOCK_V1.PDF DOCUMENTS VIEW
WILLIAMS, J. PV 6.15 KW-SPECS_V1.PDF DOCUMENTS VIEW