Permit: TC-RES-0626-03555
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
4026 S 13TH AV
Address NEW:
4026 S 13TH AV
Apply Date:
06/30/2026
Applicant:
Deanna McKinney
Description:
Property has many different types of roofing materials as well as substrate that need to be addressed. We will be re roofing both front and back dwelling each of them have space decking
Permit Reviews
Permit Number - TC-RES-0626-03555
Permit Status: Inspections
Permit Description: Property has many different types of roofing materials as well as substrate that need to be addressed. We will be re roofing both front and back dwelling each of them have space decking
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/24/2026 | RESIDENTIAL ADD/ALT v.2 | 07/31/2026 | APPROVED |
| 07/01/2026 | RESIDENTIAL ADD/ALT v.1 | 07/01/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0626-03555
Permit Status: Inspections
Permit Description: Property has many different types of roofing materials as well as substrate that need to be addressed. We will be re roofing both front and back dwelling each of them have space decking
| Date | Description | Comments |
|---|---|---|
| 07/31/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0626-03555
Permite Description: Property has many different types of roofing materials as well as substrate that need to be addressed. We will be re roofing both front and back dwelling each of them have space decking
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 08/06/2026 Roof sheathing and decking are severely damaged and exposed to weathering and will not structurally support or be able to receive fasteners. The current sheathing needs to be replaced throughout on both structures before replacing dry-in roof covering. See the IRC 2024 Section R803.1 for lumber sheathing and Chapter 9 for roof assembly requirements. |