Permit: TC-RES-0625-03036
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
5332 E 32ND ST
Address NEW:
5332 E 32ND ST
Apply Date:
06/16/2025
Applicant:
Gregory Chaisson
Description:
Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
Permit Reviews
Permit Number - TC-RES-0625-03036
Permit Status: Inspections
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/16/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 06/17/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0625-03036
Permit Status: Inspections
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
| Date | Description | Comments |
|---|---|---|
| 06/16/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0625-03036
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2025 | COT - RSEL - Electrical Final | Passed | Approved j-box and sub-panel installation |