Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
5332 E 32ND ST
Address NEW:
5332 E 32ND ST
Apply Date:
06/16/2025
Applicant:
Gregory Chaisson
Description:
Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.

Permit Reviews

Permit Number - TC-RES-0625-03036
Permit Status: Inspections
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
Start Date Submittal Complete Date Status  
06/16/2025 RESIDENTIAL SIMPLE REVIEW v.1 06/17/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0625-03036
Permit Status: Inspections
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
Date Description Comments
06/16/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0625-03036
Permit Description: Remove existing Federal Pacific Electric subpanel in the front storage closet, install a 12x12x4 inch nema 1 jbox in the place of the fpe subpanel. Run 2-14/2, 2-10/3, 3 -12/2 romex from the indoor jbox threw the attic to the main outdoor existing 100 amp siemans all in one panel. Install 2-15 amp, 2- 30 amp 2 pole, 3 -20 amp siemans breaker in the existing 100 amp outdoor main. The reason for this job is to get rid of the FPE subpanel out the storage/clothes closet.
Total Completed Inspections - 1
Date Description Inspector Results Comments
06/27/2025 COT - RSEL - Electrical Final Passed Approved j-box and sub-panel installation

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-FRANCISCA DRAWINGS_V1.PDF DOCUMENTS VIEW