Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0625-02968
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
10019 E MOONSTRUCK WY
Address NEW:
10019 E MOONSTRUCK WY
Apply Date:
06/10/2025
Applicant:
Jonathan Salcido
Description:
Install a 50A, 240V NEMA 14-50 circuit inside the garage.50A breaker in the main panel, running ~100 ft of EMT with (3) #6 and (1) #10 THHN, routing across the roof into the garage, and installing a receptacle in a junction b??.
Permit Reviews
Permit Number - TC-RES-0625-02968
Permit Status: Complete
Permit Description: Install a 50A, 240V NEMA 14-50 circuit inside the garage.50A
breaker in the main panel, running ~100 ft of EMT with (3) #6
and (1) #10 THHN, routing across the roof into the garage,
and installing a receptacle in a junction b??.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/10/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 06/11/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0625-02968
Permit Status: Complete
Permit Description: Install a 50A, 240V NEMA 14-50 circuit inside the garage.50A
breaker in the main panel, running ~100 ft of EMT with (3) #6
and (1) #10 THHN, routing across the roof into the garage,
and installing a receptacle in a junction b??.
| Date | Description | Comments |
|---|---|---|
| 06/10/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0625-02968
Permit Description: Install a 50A, 240V NEMA 14-50 circuit inside the garage.50A
breaker in the main panel, running ~100 ft of EMT with (3) #6
and (1) #10 THHN, routing across the roof into the garage,
and installing a receptacle in a junction b??.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2025 | BULD - Electrical Clearance | Passed | 240v outlet and new breakers installed per code, CLEARANCE INCR 6/16/25 | |
| 06/16/2025 | COT - RSEL - Electrical Final | Passed | 240v outlet and new breakers installed per code, CLEARANCE INCR 6/16/25 |