Permit: TC-RES-0526-02447
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3212 W VIA CAMPANA DE ORO
Address NEW:
3212 W VIA CAMPANA DE ORO
Apply Date:
05/11/2026
Applicant:
Project Manager
Description:
Installation of roof mounted solar PV System SYSTEM SIZE: DC SIZE : 19 X 410W=7.790 KW DC AC SIZE : 1 X 11500W=11.500 KW AC (19) LONGI LR5-54HPB-410M (410W) [BLK] MODULES (1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M) (1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
Permit Reviews
Permit Number - TC-RES-0526-02447
Permit Status: Complete
Permit Description: Installation of roof mounted solar PV System SYSTEM SIZE: DC SIZE : 19 X 410W=7.790 KW DC AC SIZE : 1 X 11500W=11.500 KW AC (19) LONGI LR5-54HPB-410M (410W) [BLK] MODULES (1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M) (1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/11/2026 | RESIDENTIAL SOLAR v.1 | 05/15/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0526-02447
Permit Status: Complete
Permit Description: Installation of roof mounted solar PV System SYSTEM SIZE: DC SIZE : 19 X 410W=7.790 KW DC AC SIZE : 1 X 11500W=11.500 KW AC (19) LONGI LR5-54HPB-410M (410W) [BLK] MODULES (1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M) (1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
| Date | Description | Comments |
|---|---|---|
| 05/11/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0526-02447
Permit Description: Installation of roof mounted solar PV System SYSTEM SIZE: DC SIZE : 19 X 410W=7.790 KW DC AC SIZE : 1 X 11500W=11.500 KW AC (19) LONGI LR5-54HPB-410M (410W) [BLK] MODULES (1) TESLA POWERWALL 3 (MODEL NO- 1707000-60-M) (1) TESLA BACKUP SWITCH (MODEL NO -1624171-XX-Y)
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2026 | BULD - Electrical Clearance | Passed | Approved for DGC/bat | |
| 07/01/2026 | COT - RSOL - Electrical Final Solar Project | Passed | ||
| 07/01/2026 | RSBU - Building Final | Passed |